Stability of volatile sulfur compounds (VSCs) in sampling bags - impact of temperature.

Water Sci Technol

UNSW Water Research Centre, School of Civil and Environmental Engineering, The University of New South Wales, Sydney, NSW 2052, Australia E-mail:

Published: February 2014

Volatile sulfur compounds (VSCs) are a major component of odorous emissions that can cause annoyance to local populations surrounding wastewater, waste management and agricultural practices. Odour collection and storage using sample bags can result in VSC losses due to sorption and leakage. Stability within 72 hour storage of VSC samples in three sampling bag materials (Tedlar, Mylar, Nalophan) was studied at three temperatures: 5, 20, and 30 °C. The VSC samples consisted of hydrogen sulfide (H2S), methanethiol (MeSH), ethanethiol (EtSH), dimethyl sulfide (DMS), tert-butanethiol (t-BuSH), ethylmethyl sulfide (EMS), 1-butanethiol (1-BuSH), dimethyl disulfide (DMDS), diethyl disulfide (DEDS), and dimethyl trisulfide (DMTS). The results for H2S showed that higher loss trend was clearly observed (46-50% at 24 hours) at 30 °C compared to the loss at 5 °C or 20 °C (of up to 27% at 24 hours) in all three bag materials. The same phenomenon was obtained for other thiols with the relative recoveries after a 24 hour period of 76-78% at 30 °C and 80-93% at 5 and 20 °C for MeSH; 77-80% at 30 °C and 79-95% at 5 and 20 °C for EtSH; 87-89% at 30 °C and 82-98% at 5 and 20 °C for t-BuSH; 61-73% at 30 °C and 76-98% at 5 and 20 °C for 1-BuSH. Results for other sulfides and disulfides (DMS, EMS, DMDS, DEDS) indicated stable relative recoveries with little dependency on temperature (83-103% after 24 hours). DMTS had clear loss trends (with relative recoveries of 74-87% in the three bag types after 24 hours) but showed minor differences in relative recoveries at 5, 20, and 30 °C.

Download full-text PDF

Source
http://dx.doi.org/10.2166/wst.2013.445DOI Listing

Publication Analysis

Top Keywords

relative recoveries
16
°c
13
volatile sulfur
8
sulfur compounds
8
compounds vscs
8
vsc samples
8
bag materials
8
three bag
8
stability volatile
4
vscs sampling
4

Similar Publications

Aldose reductase (ALR) is closely related to the plant's response to abiotic stresses. Previous transcriptome data from the salt-tolerant Tritipyrum Y1805 indicated that an ALR-related gene was highly upregulated under salt stress. The gene, TtALR1, was successfully cloned from Y1805, with a coding sequence length of 960 bp.

View Article and Find Full Text PDF

P2 purinergic receptors at the heart of pathological left ventricular remodeling following acute myocardial infarction.

Am J Physiol Heart Circ Physiol

January 2025

Université de Tours, Inserm UMR1327 ISCHEMIA Membrane Signalling and Inflammation in reperfusion injuries, Tours, France.

Pathological left ventricular remodeling is a complex process following an acute myocardial infarction, leading to architectural disorganization of the cardiac tissue. This phenomenon is characterized by sterile inflammation and the exaggerated development of fibrotic tissue, which is non-contractile and poorly conductive, responsible for organ dysfunction and heart failure. At present, specific therapies are lacking for both prevention and treatment of this condition, and no biomarkers are currently validated to identify at-risk patients.

View Article and Find Full Text PDF

Experiences and perspectives of patients undergoing colorectal cancer surgery: A qualitative study.

Eur J Oncol Nurs

January 2025

School of Health and Medical Sciences, City St George's, University of London, London, EC1V 0HB, United Kingdom. Electronic address:

Purpose: This study aimed to explore the experiences of patients with colorectal cancer undergoing surgical treatment, capturing their perspectives from diagnosis through to post-discharge recovery.

Methods: A qualitative methodology was adopted, utilising semi-structured virtual interviews with ten patients recruited from a specialist colorectal clinic. Interviews were transcribed verbatim, and data analysed by the process of inductive thematic analysis, using interpretive description.

View Article and Find Full Text PDF

Detection and correction of translational motion in SPECT with exponential data consistency conditions.

Phys Med Biol

January 2025

Université de Lyon, CREATIS ; CNRS UMR5220 ; Inserm U1206 ; INSA-Lyon ; Université Lyon 1, CREATIS, Centre Léon Bérard, Lyon, 69373, FRANCE.

Rigid patient motion can cause artifacts in single photon emission computed tomography (SPECT) images, compromising the diagnosis and treatment planning. Exponential data consistency conditions (eDCCs) are mathematical equations describing the redundancy of exponential SPECT measurements. It has been recently shown that eDCCs can be used to detect patient motion in SPECT projections.

View Article and Find Full Text PDF

Aim: To investigate the detection and initial management of first psychotic episodes, as well as established schizophrenia, within the primary care of the Andalusian Health System.

Background: Delay in detecting and treating psychosis is associated with slower recovery, higher relapse risk, and poorer long-term outcomes. Often, psychotic episodes go unnoticed for years before a diagnosis is established.

View Article and Find Full Text PDF