Note: A passively cooled heat pipe for spectroscopy.

Rev Sci Instrum

Laboratoire Collisions Agrégats Réactivité -IRSAMC, Université de Toulouse-UPS and CNRS UMR 5589, 118, Route de Narbonne, 31062 Toulouse Cedex, France.

Published: October 2013

We have developed and characterized a heat pipe for lithium spectroscopy, which is cooled only by air-convection, although its operating temperature is 330 °C: its construction is simple, of moderate cost and it is very reliable. A thermal model proves that heat-pipes without water cooling can be used up to considerably higher temperatures.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.4826083DOI Listing

Publication Analysis

Top Keywords

heat pipe
8
note passively
4
passively cooled
4
cooled heat
4
pipe spectroscopy
4
spectroscopy developed
4
developed characterized
4
characterized heat
4
pipe lithium
4
lithium spectroscopy
4

Similar Publications

Water Heater Type, Temperature Setting, Operational Conditions, and Insulation Affect Ecological Niches for Growth.

ACS ES T Water

January 2025

Department of Civil and Environmental Engineering, Virginia Tech, Blacksburg, Virginia 24061, United States.

Residential water heating represents an important nexus of energy/water conservation, waterborne disease, hygiene, and consumer preference. Here, we examine attributes of two off-the-shelf 151-L tank water heaters, one with hot water recirculation (recirculating) and another without recirculation (standard), compared to a tankless on-demand heater (on-demand). Energy efficiency decreased in the order on-demand > standard > continuous recirculation.

View Article and Find Full Text PDF

In this study, a novel Cu-bearing 304 stainless steel doped with 4.0 wt.% Cu (304-Cu SS) was developed, and the effects of nitrogen microalloying (304N-Cu SS) and heat treatment on mechanical, antibacterial, and corrosion properties were investigated.

View Article and Find Full Text PDF

This study investigates the feasibility of using nano-thermal rod for deicing tunnel pavements in cold region. The heating performance of the nano-thermal rod was compared with that of carbon fiber heating wire under low voltage conditions. Experimental studies were conducted in a controlled environmental chamber to evaluate the effects of arrangement parameters (spacing, buried depth, input power) and environmental factors (ambient temperature and moisture) on heating rate and effectiveness.

View Article and Find Full Text PDF

An ice slurry or an emulsion of a phase change material (PCM) is a multiphase working fluid from the so-called Latent Functional Thermal Fluid (LFTF) group. LFTF is a fluid that uses, in addition to specific heat, the specific enthalpy of the phase change of its components to transfer heat. Another fluid type has joined the LFTF group: a slurry of encapsulated phase change material (PCM).

View Article and Find Full Text PDF

This study investigates the use of multi-layered porous media (MLPM) to enhance thermal energy transfer within a counterflow double-pipe heat exchanger (DPHE). We conducted computational fluid dynamics (CFD) simulations on DPHEs featuring five distinct MLPM configurations, analyzed under both fully filled and partially filled conditions, alongside a conventional DPHE. The impact of various parameters such as porous layer arrangements, thickness, and flow Reynolds numbers on pressure drop, logarithmic mean temperature difference (LMTD), and performance evaluation criterion (PEC) was assessed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!