Temporal variability of indoor air concentrations under natural conditions in a house overlying a dilute chlorinated solvent groundwater plume.

Environ Sci Technol

School Of Sustainable Engineering and the Built Environment, Ira A. Fulton Schools of Engineering, Arizona State University, Tempe, Arizona 85287, United States.

Published: September 2015

Current vapor intrusion (VI) pathway assessment heavily weights concentrations from infrequent (monthly-seasonal) 24 h indoor air samples. This study collected a long-term and high-frequency data set that can be used to assess indoor air sampling strategies for answering key pathway assessment questions like: "Is VI occurring?", and "Will VI impacts exceed thresholds of concern?". Indoor air sampling was conducted for 2.5 years at 2-4 h intervals in a house overlying a dilute chlorinated solvent plume (10-50 μg/L TCE). Indoor air concentrations varied by 3 orders of magnitude (<0.01-10 ppbv TCE) with two recurring behaviors. The VI-active behavior, which was prevalent in fall, winter, and spring involved time-varying impacts intermixed with sporadic periods of inactivity; the VI-dormant behavior, which was prevalent in the summer, involved long periods of inactivity with sporadic VI impacts. These data were used to study outcomes of three simple sparse data sampling plans; the probabilities of false-negative and false-positive decisions were dependent on the ratio of the (action level/true mean of the data), the number of exceedances needed, and the sampling strategy. The analysis also suggested a significant potential for poor characterization of long-term mean concentrations with sparse sampling plans. The results point to a need for additional dense data sets and further investigation into the robustness of possible VI assessment paradigms. As this is the first data set of its kind, it is unknown if the results are representative of other VI-sites.

Download full-text PDF

Source
http://dx.doi.org/10.1021/es4024767DOI Listing

Publication Analysis

Top Keywords

indoor air
20
air concentrations
8
house overlying
8
overlying dilute
8
dilute chlorinated
8
chlorinated solvent
8
pathway assessment
8
air sampling
8
indoor
5
air
5

Similar Publications

We evaluated enterocyte damage (IFABP), microbial translocation (sCD14), and inflammatory responses (TNF-α, IL-6, CRP) in 16 older adults (66-78 years) during 8 hours rest in conditions simulating homes maintained at 22°C (control), the 26°C indoor temperature upper limit proposed by health agencies, and homes without air-conditioning during heatwaves (31°C, 36°C). Relative to 22°C, IFABP was elevated ~181 pg/mL after exposure to 31°C (P=0.07), and by ~378 pg/mL (P<0.

View Article and Find Full Text PDF

The Impact of the Indoor Environment on Childhood Asthma.

Curr Allergy Asthma Rep

January 2025

Division of Immunology, Department of Medicine, Boston Children's Hospital, Boston, MA, USA.

Purpose Of Review: This manuscript reviews the impact of important indoor environmental exposures on pediatric asthma, with a focus on recent literature in the field.

Recent Findings: Studies continue to support an association between numerous indoor aeroallergens and air pollutants found in homes and schools and increased asthma morbidity overall. Several recent home and school intervention studies have shown promise, though results have been overall mixed.

View Article and Find Full Text PDF

Climate change is making extreme heat events more frequent and intense. This negatively impacts many aspects of society, including organised sport. As the world's most watched sporting event, the FIFA World Cup commands particular attention around the threat of extreme heat.

View Article and Find Full Text PDF

In modern manufacturing environments, pollution management is critical as exposure to harmful substances can cause serious health issues. This study presents a two-stage computational fluid dynamic (CFD) model to estimate the distribution of pollutants in indoor production spaces. In the first stage, the Reynolds-averaged Navier-Stokes (RANS) method was used to simulate airflow and temperature.

View Article and Find Full Text PDF

Characterising Carbon Monoxide Household Exposure and Health Impacts in High- and Middle-Income Countries-A Rapid Literature Review, 2010-2024.

Int J Environ Res Public Health

January 2025

Environmental Epidemiology Team, Radiation, Chemical and Environmental Hazards Directorate, UK Health Security Agency (UKHSA), Didcot OX11 0RQ, UK.

Carbon monoxide (CO) is a toxic gas, and faulty gas appliances or solid fuel burning with incomplete combustion are possible CO sources in households. Evaluating household CO exposure models and measurement studies is key to understanding where CO exposures may result in adverse health outcomes. This assists the assessment of the burden of disease in high- and middle-income countries and informs public health interventions in higher-risk environments.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!