Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To measure the microshear bond strengths (μSBS) of composite resin to the intaglio surface of prefabricated indirect veneers and analyze the FE-SEM ultramorphology of the pretreated intaglio surfaces as well as the fracture modes.
Materials And Methods: Three veneer systems (veneer and respective luting material) were used in this study: two prefabricated veneer types, Cerinate One-hour (CER, DenMat) and Componeer (CMP, Coltene), and a laboratory- made veneer, IPS e.max Press (IPS, Ivoclar Vivadent) used as the control. For each group, 10 veneers were used. After delimitation of the bonding area with a double-faced adhesive tape, 0.8-mm-diameter cylinders of composite luting material were bonded to the pretreated intaglio surface. After polymerization, the specimens were fractured in shear mode using the wire-loop method in a universal testing machine. The pretreated intaglio surface of two extra veneers and four fractured specimens per group were morphologically characterized using FE-SEM.
Results: CER resulted in statistically lower mean μSBS (7.1 ± 1.2 MPa) than the other two veneer systems, CMP (15.2 ± 2.5 MPa) and IPS (14.7 ± 1.7 MPa) at p < 0.0001. As seen with the FE-SEM, the intaglio surface of CMP did not display microretentive features, while multiple microretentions were observed in both CER and IPS after HF etching.
Conclusion: Within the limitations of this in vitro study, the CMP and IPS veneer systems resulted in greater bond strengths than those of the CER veneer system.