The aim of the present study was to evaluate local irritant effects to rabbit skin following a single application of test samples of non-sterile polyamide non-absorbable surgical sutures POLYMED(®). The polar and nonpolar extracts were prepared by using saline solution and olive oil, respectively, after sinking the materials tested (2.0 g) in 10 ml of the corresponding liquid. Incubation was carried out at the temperature of 37 °C for 72 h. The saline solution and pure olive oil, which had no contact with the materials tested, were used as negative control samples and were incubated under the same conditions as above. Assessments of the extracts from each material were conducted on 2 albino rabbits of the New Zealand breed. On the back of each animal, 5 intracutaneous injections of the extract tested and 5 injections of the control solution, each of 0.2 ml, were carried out. The degree of irritation was scored at 4, 24, 48, 72 hours after injection and no skin changes were found. The intracutaneous irritation index (III) was calculated and yielded 0.0. Hence it was concluded that under the experimental conditions the extracts of the material tested, i.e. non-sterile polyamide non-absorbable surgical sutures POLYMED(®), were 'non-irritant' to the skin of rabbits when compared with the respective control groups. The experimental procedure was conducted according to ISO10993-10.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3798863 | PMC |
http://dx.doi.org/10.2478/intox-2013-0017 | DOI Listing |
Int J Biol Macromol
January 2025
Department of Biomedical Engineering, Research Center for Nano-biomaterials & Regenerative Medicine, College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan 030024, PR China; Shanxi-Zheda Institute of Advanced Materials and Chemical Engineering, Taiyuan 030032, PR China. Electronic address:
Tissue adhesives have attracted wide attention as alternatives to sutures. Further developments in adhesives with excellent adhesion and biocompatibility for wet tissue surfaces are still required. This study provides a new solution for the development of bioadhesives for use on tissue surfaces under wet conditions.
View Article and Find Full Text PDFJ Chromatogr B Analyt Technol Biomed Life Sci
January 2025
Department of Biological Science, Faculty of Science, Ubon Ratchathani University, Ubon Ratchathani, Thailand.
Direct thrombin inhibitors (designated as EuRL-DTIs) were partially purified from ethanol extracts of Euphorbia resinifera O.Berg latex. The obtained EuRL-DTIs comprised four major compounds: two isomers of phenolic compounds (CHO) and two amide compounds (tentatively identified as CHNO and CHNO), as identified by liquid chromatography and electrospray ionisation quadrupole time-of-flight mass spectrometry (LC-ESI-QTOF-MS/MS), attenuated total reflection-Fourier transform infrared (ATR-FTIR) spectroscopy, and/or nuclear magnetic resonance (NMR) spectroscopy.
View Article and Find Full Text PDFPhytoKeys
January 2025
Key Laboratory of Ecology and Environment in Minority Areas (Minzu University of China), National Ethnic Affairs Commission of China, Beijing 100081, China.
(Acoraceae) is a commonly used seasoning in southern China. It was previously misidentified as (Yamam.) F.
View Article and Find Full Text PDFJ Hand Microsurg
January 2025
Rothman Orthopaedic Institute, 925 Chestnut Street, Philadelphia, PA, 19107, USA.
Background: Suture selection in elective hand surgery closures has traditionally been non-absorbable sutures (NAS) rather than absorbable sutures (AS). The goal of this study was to evaluate absorbable versus non-absorbable closures of various primary elective hand procedures. Our group hypothesized that no differences in major short-term outcomes would exist.
View Article and Find Full Text PDFANZ J Surg
January 2025
General Surgical Department, Liverpool Hospital, Corner of Elizabeth and Goulburn Street, Liverpool, New South Wales, 2170, Australia.
Background: Post-operative pancreatic fistula is a common and morbid complication of pancreaticojejunal anastomosis. While gastrointestinal anastomosis is typically performed using absorbable sutures, this issue has prompted experimentation with non-absorbable sutures. This study aims to assess the available literature to provide recommendations on suture choice in this anastomosis.