An improved scheme of leucine derivative fragmentation in mass spectrometry.

Amino Acids

Laboratoire de Biochimie, Faculté de Médecine, 15 rue A. Paré, F-42023, Saint Etienne Cédex 2, France.

Published: September 1996

This study illustrates the contribution of stable isotopes to amino acid mass spectrometry. The mass spectra of natural leucine and 1(13)C leucine were compared and the mass fragmentography pattern analysed. This analysis indicates that the position of the stable isotope in tracer molecules should be very dependent on the analytical procedure used for their determination.

Download full-text PDF

Source
http://dx.doi.org/10.1007/BF00807329DOI Listing