Purpose: To evaluate the feasibility and performance of SPECT/CT arthrography of the wrist in comparison with MR arthrography in patients with suspected ulnocarpal impaction.

Methods: This prospective study included 28 wrists of 27 patients evaluated with SPECT/CT arthrography and MR arthrography. Iodine contrast medium and gadolinium were injected into the distal radioulnar and midcarpal joints. Late-phase SPECT/CT was performed 3.5 h after intravenous injection of approximately 650 MBq (99m)Tc-DPD. MR and SPECT/CT images were separately reviewed in relation to bone marrow oedema, radionuclide uptake, and tears in the scapholunate (SL) and lunotriquetral (LT) ligaments and triangular fibrocartilage complex (TFCC), and an overall diagnosis of ulnar impaction. MR, CT and SPECT/CT imaging findings were compared with each other, with the surgical findings in 12 patients and with clinical follow-up.

Results: The quality of MR arthrography and SPECT/CT arthrography images was fully diagnostic in 23 of 28 wrists (82%) and 25 of 28 wrists (89%), respectively. SPECT/CT arthrography was not diagnostic for ligament lesions due to insufficient intraarticular contrast in one wrist. MR and SPECT/CT images showed concordant findings regarding TFCC lesions in 22 of 27 wrists (81%), SL ligament in 22 of 27 wrists (81%) and LT ligament in 23 of 27 wrists (85%). Bone marrow oedema on MR images and scintigraphic uptake were concordant in 21 of 28 wrists (75%). MR images showed partial TFCC defects in four patients with normal SPECT/CT images. MR images showed bone marrow oedema in 4 of 28 wrists (14%) without scintigraphic uptake, and scintigraphic uptake was present without MR bone marrow oedema in three wrists (11%). Regarding diagnosis of ulnar impaction the concordance rate between CT and SPECT/CT was 100% and reached 96% (27 of 28) between MR and SPECT/CT arthrography. The sensitivity and specificity of MR, CT and SPECT/CT arthrography were 93%, 100% and 100%, and 93%, 93% and 93%, respectively.

Conclusion: SPECT/CT arthrography of the wrist is feasible. Regarding diagnosis of ulnar impaction we found a high concordance with MR arthrography. SPECT/CT arthrography of the wrist is an alternative to MR arthrography in patients with contraindications to MR imaging.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00259-013-2584-7DOI Listing

Publication Analysis

Top Keywords

spect/ct arthrography
36
arthrography wrist
16
bone marrow
16
marrow oedema
16
spect/ct
15
arthrography
15
arthrography patients
12
spect/ct images
12
diagnosis ulnar
12
ulnar impaction
12

Similar Publications

Diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic joint prostheses loosening.

Eur J Hybrid Imaging

February 2021

Department of Radiology and Diagnostic Imaging, University of Alberta, 2A2.41 Walter C Mackenzie Health Sciences Centre, Edmonton, Alberta, T6G 2B7, Canada.

Purpose: To evaluate the diagnostic accuracy of SPECT/CT arthrography in patients with suspected aseptic prosthesis loosening following hip and knee arthroplasty.

Methods: A retrospective review of 63 SPECT/CT arthrogram studies (36 knees and 27 hips) between February 1, 2013, and July 1, 2018, was conducted. All patients underwent clinical and radiologic evaluation as part of their assessment for persistent pain following hip and knee arthroplasty.

View Article and Find Full Text PDF

Objective: To evaluate the additional value of single-photon emission computed tomography/computed tomography arthrography compared with single-photon emission computed tomography/computed tomography alone in wrist, ankle, and knee joints.

Materials And Methods: Retrospective evaluation of 68 patients including 74 joints (48 wrists, 13 upper ankle (talocrural joint), and 13 knee joints) was performed. Activity in single-photon emission computed tomography/computed tomography images was graded using a four-point scale: 0 no uptake, one low uptake, two moderate uptake, and three high uptake.

View Article and Find Full Text PDF

Objective: The aim of this study was to compare the diagnostic accuracy of nuclear imaging modalities in the detection of aseptic loosening of total knee arthroplasty (TKA).

Materials And Methods: MEDLINE, EMBASE, and the Cochrane Database of Systematic Reviews were searched from database inception to December 2018 in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines. Included studies compared the results of a single imaging modality against an appropriate reference standard of prosthetic TKA loosening, with sufficient information to determine either sensitivity and/or specificity.

View Article and Find Full Text PDF

SPECT/CT in the Postoperative Painful Knee.

Semin Nucl Med

September 2018

Department of Nuclear Medicine, Hôpital Lariboisière, Assistance Publique-Hôpitaux de Paris, Paris, France.

This review summarizes the role of SPECT/CT in patients with a painful postoperative knee and describes typical diagnostic criteria in these patients. Pain after knee surgery is common and is influenced by the underlying pathology, the type of surgery, and the patient. Knee joint-preserving surgery includes osteotomy, ligament reconstruction, meniscus surgery, and cartilage repair procedures, often used in combination.

View Article and Find Full Text PDF

SPECT/CT in Postoperative Hand and Wrist Pain.

Semin Nucl Med

September 2018

Department of Nuclear Medicine, Antwerp University Hospital, Edegem, Belgium; Faculty of Medicine and Health Sciences, University of Antwerp, Wilrijk, Belgium.

In this review we summarize the current evidence and experience regarding the performance of SPECT/CT in the evaluation of patients with postoperative painful wrist or hand. There is a wide range of operative wrist and hand interventions due to congenital, traumatic, degenerative, or inflammatory diseases. A significant number of patients suffer from pain after operative procedures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!