Purpose: In emergency endovascular repair (EVAR) of ruptured aneurysms of the aorta (rAAA), anatomical suitability must be determined. Semiautomatic three-dimensional assessment of the aortoiliac arteries has the potential to standardise measurements. This study assesses the fitness for purpose of such a semiautomatic approach for rAAA and determined interobserver agreement on suitability.

Materials And Methods: Interobserver study with six trained observers (4 vascular surgeons, 2 radiologists) blindly assessing preoperative computed tomography angiography scans of 50 consecutive patients with rAAA. A central lumen line (CLL) was generated, and perpendicular diameters, length along the CLL, and EVAR suitability were determined using dedicated sizing software (3mensio; 3mensio Vascular; Bilthoven, The Netherlands). Success of generating a CLL, time of assessment, and interobserver agreement was determined.

Results: In the majority of the patients (median 76 %, range 64-78 %), a CLL was semiautomatically generated. The median duration of CLL generation and performance measurements was 7.5 min (interquartile range 5.5-10.6). Agreement on suitability was moderate for the entire group (Fleiss' κ = 0.55, confidence interval 0.48-0.62) and ranged from moderate to good (Cohen's κ = 0.40-0.72) between observer pairs.

Conclusion: Assessing EVAR suitability of rAAA patients using dedicated sizing software is possible in the majority of patients. The measurements can be performed in a reasonable amount of time, and the agreement of suitability for EVAR in patients with rAAA is moderate. Improvements and additional research are necessary to replace the current axial measurement.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00270-013-0757-1DOI Listing

Publication Analysis

Top Keywords

sizing software
12
emergency endovascular
8
suitability determined
8
interobserver agreement
8
patients raaa
8
evar suitability
8
dedicated sizing
8
majority patients
8
agreement suitability
8
raaa
5

Similar Publications

Effect of head size, head material, and radiation dose on the repeatability of CT-RSA measurements of femoral head penetration.

J Mech Behav Biomed Mater

January 2025

Division of Orthopaedic Surgery, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada; Department of Medical Biophysics, Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada. Electronic address:

Background: The risk of early revision of total hip arthroplasty (THA) for polyethylene wear is now low, but there remains a need to perform wear measurements in patients for clinical surveillance. The gold standard of wear measurements has been radiostereometric analysis (RSA), which has limited availability. The use of computed tomography (CT) to perform THA wear measurement was described a decade ago and found to have acceptable accuracy and precision, but high radiation dose was a concern.

View Article and Find Full Text PDF

The heating oil circuit plays an essential role in the heating calendering roller for the lithium battery pole piece. To achieve the optimization of the heating oil circuit, a fluid-thermal-structural coupling method and a multi-objective optimization procedure are proposed to obtain the optimal solution. A fluid-thermal-structural coupling flowchart based on the numerical modeling for the calendering roller temperature distribution is created to automate the analysis processes in the optimization iteration.

View Article and Find Full Text PDF

Standardization of the Agar Plate Method for Bacteriophage Production.

Antibiotics (Basel)

December 2024

Laboratory of Aquatic Biomedicine, College of Veterinary Medicine and Research Institute for Veterinary Science, Seoul National University, Seoul 08826, Republic of Korea.

The growing threat of antimicrobial resistance (AMR), exacerbated by the COVID-19 pandemic, highlights the urgent need for alternative treatments such as bacteriophage (phage) therapy. Phage therapy offers a targeted approach to combat bacterial infections, particularly those resistant to conventional antibiotics. This study aimed to standardize an agar plate method for high-mix, low-volume phage production, suitable for personalized phage therapy.

View Article and Find Full Text PDF

Objective: The triply periodic minimal surface (TPMS) Gyroid porous scaffolds were built with identical porosity while varying pore sizes were used by fluid mechanics finite element analysis (FEA) to simulate the microenvironment. The effects of scaffolds with different pore sizes on cell adhesion, proliferation, and osteogenic differentiation were evaluated through calculating fluid velocity, wall shear stress, and permeability in the scaffolds.

Methods: Three types of gyroid porous scaffolds, with pore sizes of 400, 600 and 800 μm, were established by nTopology software.

View Article and Find Full Text PDF

The effects of Pistacia atlantica Desf. fruit oil on primary knee osteoarthritis: A randomized controlled clinical trial.

J Ethnopharmacol

January 2025

Traditional Medicine and History of Medical Sciences Research Center, Health Research Institute, Babol University of Medical Sciences, Babol. Iran. Electronic address:

Ethnopharmacological Relevance: Pistacia atlantica Desf. (Baneh) is a native tree in many areas of Iran such as Zagros mountains and Sistan va Baluchestan Province. It is famous mostly due to its oleo-gum resin and there are many studies on its effects on gastrointestinal disorders and musculoskeletal problems.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!