Aims: To determine if 'Defocus Incorporated Soft Contact' (DISC) lens wear slows childhood myopia progression.
Methods: A 2-year double-blind randomised controlled trial was carried out in 221 children aged 8-13 years, with myopia between -1.00 and -5.00 Dioptres (D) and astigmatism ≤1.00 D. Subjects were randomly assigned to the DISC (n=111) or single vision (SV; n=110) contact lens group. DISC lenses incorporated concentric rings, which provided an addition of +2.50 D, alternating with the normal distance correction. Refractive error (cycloplegic autorefraction) and axial length were measured at 6-month intervals. Differences between groups were analysed using unpaired t test.
Results: In total, 128 children completed the study, n=65 in the DISC group and n=63 in the SV group. Myopia progressed 25% more slowly for children in the DISC group compared with those in the control group (0.30 D/year; 95% CI -0.71 to -0.47 vs 0.4 D/year; 95% CI -0.93 to -0.65, p=0.031). Likewise, there was less axial elongation for children in the DISC versus SV groups (0.13 mm/year; 95% CI 0.20 to 0.31 vs 0.18 mm/year; 95% CI 0.30 to 0.43, p=0.009). Treatment effect correlated positively with DISC lens wearing time (r=0.342; p=0.005). Indeed, myopia in children who wore the DISC lenses for five or more hours/day progressed 46% (mean difference=-0.382 D, p=0.001; 95% CI -0.59 to -0.17) less than those in the SV group.
Conclusions: The daily wearing of DISC lens significantly slowed myopia progression and axial elongation in Hong Kong schoolchildren. The findings demonstrated that simultaneous clear vision with constant myopic defocus can retard myopia progression.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3888618 | PMC |
http://dx.doi.org/10.1136/bjophthalmol-2013-303914 | DOI Listing |
J Contemp Brachytherapy
October 2024
Department of Radiation Oncology, East Carolina University, Greenville, North Carolina, USA.
Purpose: To investigate sensitivity of contributing factors to heterogeneity corrections in ocular brachytherapy using iodine-125 (I) Collaborative Ocular Melanoma Study (COMS) plaques.
Material And Methods: Using egs_brachy, Monte Carlo (MC) simulations were performed for I COMS plaques (model: IsoAid IAI-125A). Homogeneous dose (D) was estimated under the American Association of Physicists in Medicine Task Group-43 assumptions, with 85 Gy prescribed to a 5 mm depth.
Cont Lens Anterior Eye
December 2024
Optometry and Vision Science Research Groups (OVSRG), School of Optometry, College of Health and Life Sciences, Aston University, Birmingham, UK. Electronic address:
Antibiotic eyedrops typically require frequent instillation due to the eye's defensive mechanisms limiting drugs from reaching target sites. This may risk patient non-adherence and treatment inefficacy. The aim of this study was to develop a biocompatible and fully soluble ocular film insert to enhance the delivery of levofloxacin, as well as the handling procedure for its administration; based on the anatomical dimensions and physiological conditions of the human eye.
View Article and Find Full Text PDFData Brief
December 2024
UR Optimisation des Procédés en Agro-alimentaire, Agriculture et Environnement (OPAALE), INRAE, Rennes, France.
The present dataset combines transcriptomic and microscopic analyses to investigate the responses of winter oilseed rape (WOSR, Brassica napus L., cultivar Aviso) to soil drought, with a focus on differences between young and early-senescent old leaves. For microscopy, 36 scans of 1 to 5 leaf cross-sections were acquired from paraffin-embedded leaf disc samples using a scanner with a 40x lens (Pannoramic Confocal, 3DHistech), capturing a large field of view (8-mm-long observed leaf tissue).
View Article and Find Full Text PDFAsia Pac J Ophthalmol (Phila)
December 2024
Singapore National Eye Centre, Singapore; Eye Academic Clinical Programme (ACP), Duke-NUS Graduate Medical School, Singapore. Electronic address:
Purpose: This study aimed to investigate the longitudinal associations between myopic optic disc features and optical coherence tomography (OCT) measurements of peripapillary retinal nerve fibre layer (RNFL) thickness in young myopic children in Singapore.
Methods: A prospective, single-site cohort study was conducted, involving children aged 7-16 years who participated in the PROM-Kids clinical cohort study from 2019 to 2022. Participants underwent annual assessments, including cycloplegic refraction, axial length measurements, fundus photography, and OCT imaging, with ocular magnification correction.
Sci Rep
November 2024
Eye Institute of Shandong First Medical University, Qingdao Eye Hospital of Shandong First Medical University, 5 Yanerdao Road, Qingdao, 266071, China.
This study aims to quantify fundus tessellated (FT) density and optic disc (OD) morphology using deep learning (DL) techniques and to investigate the correlations between these fundus characteristics and refractive function in young patients with myopia. We constructed two DL-based segmentation models to delineate the FT, OD, peripapillary atrophy (PPA), and macula at a pixel-level resolution. The study sought to identify differences in fundus characteristics between eyes categorized as having high myopia versus mild or moderate myopia.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!