A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A propensity score matched analysis to determine if second-generation drug-eluting stents outperform first-generation drug-eluting stents in a complex patient population. | LitMetric

Background: Drug-eluting stents (DES) are routinely used in complex patients, but the impact of 1st- versus 2nd-generation DES on clinical outcomes has not been well described. This study aimed to assess the efficacy and safety of 2nd-generation (everolimus-eluting) DES compared to 1st-generation (sirolimus- and paclitaxel-eluting) DES in a selected, higher-risk population with complex clinical and angiographic features.

Methods: The study included 5693 consecutive patients with the presence of ≥ 1 predefined complex clinical and angiographic characteristic treated with either generation DES. Using propensity score matching, the clinical outcomes of 1076 patients treated with 2nd-generation DES were compared with the outcomes of a matched population treated with 1st-generation DES over 1-year follow-up.

Results: After matching, baseline clinical and angiographic characteristics were similar between groups. At 1-year follow-up, the rate of major adverse cardiac events was 9.4% with 2nd-generation DES and 11.3% with 1st-generation DES (p=0.16). There were no significant differences in the rates of death (3.2 vs. 4.0%, p=0.30), myocardial infarction (1.6 vs. 1.3%, p=0.57), target vessel revascularization (5.9 vs. 7.3%, p=0.17) or target lesion revascularization (4.4 vs. 5.0%, p=0.50). Definite stent thrombosis was less frequent with 2nd-generation DES (0.1 vs. 0.8%, p=0.011), as was definite or probable stent thrombosis (0.7 vs. 1.6%, p=0.040).

Conclusion: In this propensity score matched patient population with complex features undergoing percutaneous coronary intervention, the use of 2nd-generation DES was associated with lower rates of stent thrombosis, and similar 1-year major adverse cardiac events compared to 1st-generation DES.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijcard.2013.10.004DOI Listing

Publication Analysis

Top Keywords

2nd-generation des
20
propensity score
12
drug-eluting stents
12
des
12
clinical angiographic
12
1st-generation des
12
stent thrombosis
12
score matched
8
patient population
8
clinical outcomes
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!