A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel method for high throughput lipophilicity determination by microscale shake flask and liquid chromatography tandem mass spectrometry. | LitMetric

A novel method for high throughput lipophilicity determination by microscale shake flask and liquid chromatography tandem mass spectrometry.

Comb Chem High Throughput Screen

Genentech, Inc., 1 DNA Way, South San Francisco, California, 94080-4990, USA.

Published: December 2013

Modern small molecule drug design requires the optimization of not only the binding characteristics of the molecule but also its physicochemical properties for ADMET performance. A key physical property is lipophilicity and medicinal chemists need rapid access to high quality data in order to drive their decision making. Traditionally lipophilicity (log D) measurements are performed with a shake flask method and UV determination. This method suffers from low sensitivity and is not easily converted to a high throughput format. Over the past decade, several groups have taken different approaches to improve this assay, including replacing the shake flask method with one that utilizes reverse phase HPLC. Here we describe a new microscale shake flask method that utilizes UPLC-MS/MS to achieve increased throughput, sensitivity and accuracy. Approaches for assessing data quality are also described. This platform technology only requires micrograms of compound and is routinely used by most small molecule drug discovery project teams at Genentech.

Download full-text PDF

Source
http://dx.doi.org/10.2174/1386207311301010007DOI Listing

Publication Analysis

Top Keywords

shake flask
16
flask method
12
high throughput
8
microscale shake
8
small molecule
8
molecule drug
8
method utilizes
8
novel method
4
method high
4
throughput lipophilicity
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!