The optical nonlinearities of six non-peripherally-substituted pyridyloxy phthalocyanines have been studied at 532 nm using a nanosecond Z-scan technique in a dimethyl sulphoxide solution. Ring-strain effects and the absence of a metal center were found to greatly reduce the inherent high nonlinearities expected of some of these phthalocyanine complexes. Of the six molecules investigated, 1(4),8(11),15(18),22(25)-tetrakis-(2-pyridyloxy)phthalocyaninato lead(II) 3, 1(4),8(11),15(18),22(25)-tetrakis-(2-pyridyloxy)phthalocyanine 5, and 1(4),8(11),15(18),22(25)-tetrakis-(4-pyridyloxy)phthalocyanine 6 were found to exhibit negligible nonlinear optical behavior, due to either the absence of asymmetry or central metal and/or the presence of a ring-strain effect. A two-photon absorption process was found to be the major contributor to the observed reverse saturable absorption (RSA) in 1(4),8(11),15(18),22(25)-tetrakis-(4-pyridyloxy)phthalocyaninato lead(II) 4, 1(4)-mono-(2-pyridyloxy)phthalocyaninato lead(II) 7, and 1(4)-mono-(4-pyridyloxy)phthalocyaninato lead(II) 8, with large two-photon absorption cross-section, high hyperpolarizability and high third-order susceptibility values in the range of 4.53 × 10(-43)-5.33 × 10(-42) cm(4) s per photon, 1.61 × 10(-28)-1.89 × 10(-27) esu and 9.73 × 10(-12)-7.05 × 10(-11) esu respectively.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1039/c3dt52462k | DOI Listing |
Nano Lett
January 2025
Department of Electrical and Computer Engineering, Northwestern University, Evanston, Illinois 60208, United States.
Metasurfaces supporting narrowband resonances are of significant interest in photonics for molecular sensing, quantum light source engineering, and nonlinear photonics. However, many device architectures rely on large refractive index dielectric materials and lengthy fabrication processes. In this work, we demonstrate quasi-bound states in the continuum (quasi-BICs) using a polymer metasurface exhibiting experimental quality factors of 305 at visible wavelengths.
View Article and Find Full Text PDFNat Commun
January 2025
Research Laboratory of Electronics, MIT, Cambridge, MA, USA.
Three-dimensional subcellular imaging is essential for biomedical research, but the diffraction limit of optical microscopy compromises axial resolution, hindering accurate three-dimensional structural analysis. This challenge is particularly pronounced in label-free imaging of thick, heterogeneous tissues, where assumptions about data distribution (e.g.
View Article and Find Full Text PDFLight Sci Appl
January 2025
Laboratoire Matériaux et Phénomènes Quantiques, Université Paris Cité and CNRS, Paris, 75013, France.
Vortex beams are currently drawing a great deal of interest, from fundamental research to several promising applications. While their generation in bulky optical devices limits their use in integrated complex systems, metasurfaces have recently proven successful in creating optical vortices, especially in the linear regime. In the nonlinear domain, of strategic importance for the future of classical and quantum information, to date orbital angular momentum has only been created in qualitative ways, without discussing discrepancies between design and experimental results.
View Article and Find Full Text PDFLight Sci Appl
January 2025
Spin-Optics laboratory, St. Petersburg State University, St. Petersburg, 198504, Russia.
We introduce a novel neuromorphic network architecture based on a lattice of exciton-polariton condensates, intricately interconnected and energized through nonresonant optical pumping. The network employs a binary framework, where each neuron, facilitated by the spatial coherence of pairwise coupled condensates, performs binary operations. This coherence, emerging from the ballistic propagation of polaritons, ensures efficient, network-wide communication.
View Article and Find Full Text PDFScience
January 2025
Department of Electrical, Computer and Energy Engineering, University of Colorado Boulder, Boulder, CO, USA.
Optical frequency combs have enabled unique advantages in broadband, high-resolution spectroscopy and precision interferometry. However, quantum mechanics ultimately limits the metrological precision achievable with laser frequency combs. Quantum squeezing has led to significant measurement improvements with continuous wave lasers, but experiments demonstrating metrological advantage with squeezed combs are less developed.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!