A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Frequency and collective dose of medical procedures in Kenya. | LitMetric

Frequency and collective dose of medical procedures in Kenya.

Health Phys

*Department of Physics and Applied Physics, University of Massachusetts Lowell, One University Avenue, Lowell, MA 01854; †Radiology Department, Kenyatta National Hospital, Hospital Road, P.O. Box 20723-00202 Nairobi, Kenya; ‡National Nuclear Regulator, Eco Glades 2 Office Park, Block G, Eco Park, Centurion, 0157 South Africa.

Published: December 2013

The first comprehensive national survey on frequency and radiation dose imparted to the population from radiological procedures was carried out in Kenya and reported here. This survey involved assessment of frequency, typical patient radiation exposure, and collective effective dose from general radiography, fluoroscopy, interventional procedures (IPs), mammography, and computed tomography. About 300 x-ray facilities across the country were invited to participate in the survey, and a 31% response was recorded. The individual and collective radiation burdens of more than 62 types of pediatric and adult radiological examinations were quantified using effective and collective dose. The average effective dose for each radiological examination was assessed from the x-ray efficiency performance tests and patient data from over 30 representative radiological facilities. The results found indicated that over 3 million x-ray procedures were performed in 2011, resulting in an annual collective effective dose of 2,157 person-Sv and an annual effective dose per capita of 0.05 mSv. The most frequent examinations were general radiography (94%), computed tomography (3.3%), and fluoroscopy (2.5%). Although the contribution of computed tomography was small in terms of frequency, this procedure accounted for 36% of the effective dose per capita. General radiography was the most frequent type of examination with a contribution of 55% of the effective dose per capita.

Download full-text PDF

Source
http://dx.doi.org/10.1097/HP.0b013e31829c35f4DOI Listing

Publication Analysis

Top Keywords

effective dose
24
general radiography
12
computed tomography
12
dose capita
12
dose
9
collective dose
8
collective effective
8
effective
7
frequency
4
frequency collective
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!