Background And Purpose: Stereotactic ablative body radiotherapy (SABR) is an emerging treatment modality for primary renal cell carcinoma. To account for respiratory-induced target motion, an internal target volume (ITV) concept is often used in treatment planning of SABR. The purpose of this study is to assess patterns of kidney motion and investigate potential surrogates of kidney displacement with the view of ITV verification during treatment.

Material And Methods: Datasets from 71 consecutive patients with free breathing four-dimensional computed tomography (4DCT) planning scans were included in this study. The displacement of the left and right hemi-diaphragm, liver dome and abdominal wall were measured and tested for correlation with the displacement of the both kidneys and patient breathing frequency.

Results: Nine patients were excluded due to severe banding artifact. Of 62 evaluable patients, the median age was 68 years, with 41 male patients and 21 female patients. The mean (range) of the maximum, minimum and average breathing frequency throughout the 4DCTs were 20.1 (11-38), 15.1 (9-24) and 17.3 (9-27.5) breaths per minute, respectively. The mean (interquartile range) displacement of the left and right kidneys was 0.74 cm (0.45-0.98 cm) and 0.75 cm (0.49-0.97) respectively. The amplitude of liver-dome motion was correlated with right kidney displacement (r=0.52, p<0.001), but not with left kidney displacement (p=0.796). There was a statistically significant correlation between the magnitude of right kidney displacement and that of abdominal displacement (r=0.36, p=0.004), but not the left kidney (r=0.24, p=0.056). Hemi-diaphragm displacements were correlated with kidney displacements respectively, with a weaker correlation for the left kidney/left diaphragm (r=0.45, [95% CI 0.22 to 0.63], p=<0.001) than for the right kidney/right diaphragm (r=0.57, [95% CI 0.37 to 0.72], p=<0.001).

Conclusions: For the majority of patients, maximal left and right kidney displacement is subcentimeter in magnitude. The magnitude of kidney motion cannot be reliably estimated from the diaphragmatic, liver dome or abdominal wall surrogates. One explanation may be that the kidneys are not uniformly in contact with the surrogates investigated in this study. Further investigation is required before surrogates of kidney displacement are used for clinical SABR delivery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3829388PMC
http://dx.doi.org/10.1186/1748-717X-8-248DOI Listing

Publication Analysis

Top Keywords

kidney motion
8
four-dimensional computed
8
computed tomography
8
kidney displacement
8
displacement left
8
kidney
5
displacement
5
patients
5
analysis respiratory
4
respiratory induced
4

Similar Publications

Case 333: Masson Tumor.

Radiology

January 2025

From the Departments of Radiology (V.K., A.R., P.D.) and Pathology (J.N.), University of Arkansas for Medical Sciences, 4301 W Markham St, Little Rock, AR 72205.

A 61-year-old male patient without prior history of ophthalmologic problems presented with pain and redness in the left eye associated with slowly progressive proptosis over the previous 6 months. The patient also had diplopia in rightward and downward gaze. There was no vision loss.

View Article and Find Full Text PDF

Objective: To explore the potential of Intravoxel Incoherent Motion Diffusion (IVIM) and Arterial Spin Labeling (ASL) in predicting the short-term effectiveness of post-revascularization for severe atherosclerotic renal artery stenosis.

Material And Methods: A retrospective analysis of 88 cases from October 2018 to February 2023 was conducted. Patients were divided into Responder and Non-Responder groups based on renal function outcomes at their last follow-up.

View Article and Find Full Text PDF

Introduction: Manipulation under anesthesia (MUA) is a standard and effective treatment to correct stiffness and improve range of motion (ROM) following total knee arthroplasty (TKA). Delayed MUA has been associated with increased rates of revision surgeries and infections. Early MUA has been shown to double the mean gain in flexion compared to delayed interventions.

View Article and Find Full Text PDF

Purpose: Redox homeostasis plays a key role in regulating the overall health and development of organisms. This study aimed to develop a compact and mobile continuous-wave (CW) electron paramagnetic resonance (EPR) imager to facilitate stable, highly sensitive fast three-dimensional (3D) whole-body imaging of nitroxide-infused mice.

Methods: A multiturn loop gap resonator with a diameter of 30 mm and length of 35 mm was designed for whole-body EPR imaging.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!