A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Design and development of trace Cr(VI) sensor]. | LitMetric

[Design and development of trace Cr(VI) sensor].

Guang Pu Xue Yu Guang Pu Fen Xi

Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei 231500, China.

Published: August 2013

Hexavalent chromium detection in medicine capsules is generally analyzed in the laboratory, it is difficult to meet the demand for field detection, and to address this problem, a sensor which can be used for on-site detection of trace amounts of hexavalent chromium was designed. It mainly includes chemically sensitive materials, optical sensing module and signal processing module, the chemical sensitive materials is to achieve the conversion of the hexavalent chromium concentration signal, the optical sensing module is to complete a stable output of the laser light source, and the signal processing module is to complete a photoelectric conversion of the weak fluorescence signal, signal amplification, and data processing and displaying. With using the indigenously developed photoelectric acquisition, conversion and signal processing system to complete the rapid detection of trace amounts of hexavalent chromium, so the miniaturization of testing instruments and on-site detection were achieved. Experimental results show that: the sensor detection results have a good linear relationship when the hexavalent chromium concentration is 10-500 microg x L(-1), the linear equation is Y = 1.542 47 x X-2.353 47, and the linearity is 0.998 62, the detection limit reaches 10 microg x L(-1), the sensor response time is about 90 seconds, 5 capsule samples were selected to do the contrast detection, and the results show that the sensor quantitative detection data is reliable, which meets trace hexavalent low cost, fast and field detection demands.

Download full-text PDF

Source

Publication Analysis

Top Keywords

hexavalent chromium
20
signal processing
12
detection
10
field detection
8
on-site detection
8
detection trace
8
trace amounts
8
amounts hexavalent
8
sensitive materials
8
optical sensing
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!