Theory of effective drug release from medical implants based on the Higuchi model and physico-chemical hydrodynamics.

Colloids Surf A Physicochem Eng Asp

NovaFlux Technologies, 1 Wall Street, Princeton, NJ 08540, USA.

Published: September 2012

Combining the approach of colloid transport with the generalized Higuchi theory of drug release and with the concept of minimum inhibitory concentration (MIC) known in microbiology, the theory of effective drug release from implants has been developed. Effective release of an antibiotic at a concentration above MIC is a necessary condition to achieve protection against infection from implants such as central catheters. The Higuchi theory in its present form is not predictive of the therapeutic effect from medical implants. The theory of effective release presented in this paper specifies two release modes, namely: one with therapeutic usefulness (effective release) and another without therapeutic effect. Therapeutic usefulness may be achieved when the antibiotic concentration, , on the implant surface kills the organisms of interest and prevents the formation and propagation of biofilm when exceeds the corresponding MIC of the released antibiotic compound. Currently, neither the Higuchi theory nor any other theory can provide such prediction. The present approach requires quantification of the antibiotic transport from the drug-polymer blend implant surface into the tissue and accounts for its coupling with drug diffusion inside the blend, a task that has not been developed in existing theories. Our solution to this task resulted in the derivation of an equation for the time of duration of effective release, , which depends on MIC, the Higuchi invariant and the characteristics of convective diffusion within the tissue. The latter characteristics include: diffusivity and diffusion layer thickness δ which is controlled by the velocity of the interstitial fluid in tissue. A smaller is favorable because transport from the catheter surface is weaker, while a thinner diffusion layer is harmful because this transport is stronger. The influence of the tangential component of interstitial velocity in the tissue is especially harmful because the diffusion within the incision exit site (IES) will be extremely enhanced such that it may decrease to zero. The incorporation of convective diffusion into the theory of antibacterial protection by means of antibiotic release has revealed that physicochemical mechanisms predict the effectiveness of antibiotic-loaded catheters and defines the conditions necessary to achieve better protection by means of combining the level of catheter loading with antibiotics and the use of wound (IES) dressing.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3804347PMC
http://dx.doi.org/10.1016/j.colsurfa.2012.04.040DOI Listing

Publication Analysis

Top Keywords

effective release
16
theory effective
12
drug release
12
higuchi theory
12
release
9
theory
8
effective drug
8
medical implants
8
concentration mic
8
antibiotic concentration
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?