Background: Percutaneous trigeminal rhizotomy (PTR) uses fluoroscopic guidance to cannulate the foramen ovale for the treatment of trigeminal neuralgia.

Objective: To describe the use of a high-resolution biplane neuroangiosuite for PTR and retrospectively to assess the performance of this technique.

Methods: From 1990 through 2010, 67 PTRs were performed in 51 patients at our institution; 47 used the c-arm in the operating room (OR) and 20 used the biplane angiosuite. Hospital charts were reviewed for demographics, symptomatology, operative time, number of cannulation attempts, fluoroscopy time and pain outcome. Two-tailed univariate analyses were performed to compare the OR and angiosuite groups.

Results: In 20 of 67 PTRs, biplane fluoroscopic guidance in the angiosuite was used. Variations in type of PTR, fluoroscopy technique and follow-up time barred meaningful comparison of these variables between OR and biplane groups. However, the biplane group had significantly fewer mean cannulation attempts (1 vs 2.2, p<0.001).

Conclusions: High-resolution biplane neuroangiosuites offer a readily available alternative to ORs for PTR in the treatment of trigeminal neuralgia. Use of the biplane fluoroscopy machine was practical, safe and at least as effective as the use of the c-arm. It may also offer the advantages of a reduced number of cannulation attempts.

Download full-text PDF

Source
http://dx.doi.org/10.1136/neurintsurg-2013-010883DOI Listing

Publication Analysis

Top Keywords

percutaneous trigeminal
8
trigeminal rhizotomy
8
biplane angiosuite
8
fluoroscopic guidance
8
cannulation attempts
8
biplane
6
rhizotomy biplane
4
angiosuite
4
angiosuite technical
4
technical assessment
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!