The pulmonary oxygen uptake (VO2) response to incremental-ramp cycle ergometry typically demonstrates lagged-linear first-order kinetics with a slope of ~10-11 ml·min(-1)·W(-1), both above and below the lactate threshold (θL), i.e. there is no discernible VO2 slow component (or "excess" VO2) above θL. We were interested in determining whether a reverse ramp profile would yield the same response dynamics. Ten healthy males performed a maximum incremental -ramp (15-30 W·min(-1), depending on fitness). On another day, the work rate (WR) was increased abruptly to the incremental maximum and then decremented at the same rate of 15-30 W.min(-1) (step-decremental ramp). Five subjects also performed a sub-maximal ramp-decremental test from 90% of θL. VO2 was determined breath-by-breath from continuous monitoring of respired volumes (turbine) and gas concentrations (mass spectrometer). The incremental-ramp VO2-WR slope was 10.3 ± 0.7 ml·min(-1)·W(-1), whereas that of the descending limb of the decremental ramp was 14.2 ± 1.1 ml·min(-1)·W(-1) (p < 0.005). The sub-maximal decremental-ramp slope, however, was only 9. 8 ± 0.9 ml·min(-1)·W(-1): not significantly different from that of the incremental-ramp. This suggests that the VO2 response in the supra-θL domain of incremental-ramp exercise manifest not actual, but pseudo, first-order kinetics. Key pointsThe slope of the decremental-ramp response is appreciably greater than that of the incremental.The response dynamics in supra-θL domain of the incremental-ramp appear not to manifest actual first-order kinetics.The mechanisms underlying the different dynamic response behaviour for incremental and decremental ramps are presently unclear.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3737826 | PMC |
Scand J Clin Lab Invest
January 2025
Centre for Physical Activity Research, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark.
The objective of the current review was to identify whether clinically established lung function metrics of ventilatory and diffusion capacity obtained by standardised methodology are consistent with superior lung function in athletes, and whether this is related to maximal oxygen uptake (V̇O). Three independent reviewers performed a literature search in PubMed, Scopus, and reference screening. Data was extracted and analysed according to a predefined strategy.
View Article and Find Full Text PDFClin Physiol Funct Imaging
January 2025
Centre for Physical Activity Research, Copenhagen University Hospital - Rigshospitalet, Copenhagen, Denmark.
Background: Cardiopulmonary exercise testing (CPET) is usually considered the gold standard for assessing maximal oxygen consumption (V̇O), a health and performance marker in patients with chronic obstructive pulmonary disease (COPD). Despite the widespread application of CPET, the absolute and relative test-retest reliability of CPET-derived metrics remains unexamined.
Objective: To examine and compare test-retest reliability of CPET derived metrics in individuals with COPD and healthy matched controls.
Sci Rep
January 2025
Animal Genomics Laboratory, Animal Biotechnology Division, ICAR-National Dairy Research Institute, Karnal, Haryana, India.
Poor male fertility significantly affects dairy production, primarily due to low conception rates (CR) in bulls, even when cows are inseminated with morphologically normal sperm. Seminal plasma is a key factor in evaluating the fertilizing ability of bull semen. The extracellular vesicles (EVs) in seminal plasma contain fertility-associated proteins like SPAM1, ADAM7, and SP10, which influence sperm function and fertilizing potential.
View Article and Find Full Text PDFEcotoxicol Environ Saf
January 2025
State Key Laboratory of Pollution Control and Resource Reuse, School of the Environment, Nanjing University, Nanjing 210023, China.
The abrasion of melamine cleaning sponges release microplastic fibers (MPFs) into the environment, yet the potential risks remain unknown. Here, we evaluated the ingestion, elimination, and toxic effects of melamine MPFs on Daphnia magna through acute and chronic exposures. This new type of MPFs displayed different morphology (a combination of linear and branched fibers with a length ranging from 10 to 157 μm) from the widely-studied MPFs released from textiles (longer and thicker linear fibers but no branched fibers).
View Article and Find Full Text PDFAdv Sci (Weinh)
January 2025
Hunan Provincial Key Laboratory of Animal Intestinal Function and Regulation, Hunan international joint laboratory of Animal Intestinal Ecology and Health, Laboratory of Animal Nutrition and Human Health, College of Life Sciences, Hunan Normal University, Changsha, 410081, China.
Aspartate (Asp) metabolism-mediated antioxidant functions have important implications for neonatal growth and intestinal health; however, the antioxidant mechanisms through which Asp regulates the gut microbiota and influences RIP activation remain elusive. This study reports that chronic oxidative stress disrupts gut microbiota and metabolite balance and that such imbalance is intricately tied to the perturbation of Asp metabolism. Under normal conditions, in vivo and in vitro studies reveal that exogenous Asp improves intestinal health by regulating epithelial cell proliferation, nutrient uptake, and apoptosis.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!