This paper discusses the role of knee positioning and range-of- motion on the closed-stance forehand tennis swing. The analyses of tennis swing mechanics were performed using a computer model comprised of a full-body model of a human and an inertial model of a racket. The model was driven by subject forehand swings (16 female college-level subjects) recorded with a high-speed digital motion analysis system. The study discovered that both initial knee positioning and range-of-motion were positively related to racket velocity and characteristic of more skilled players. The direct effects of knee positioning and range-of-motion on racket movement are minimal, however there are several indirect biomechanical effects on the forehand motion such as movement of the body mass center, work of the knee, hip and back joints, and the angular range-of-motion of the hips and torso. Some of these indirect effects were related to racket velocity and characteristic of more skilled players. Factors that influenced knee positioning and range-of-motion include years of playing, amount of coaching, and body style. Efforts to both increase and restrict the knee movements of the subjects resulted in substantially lower racket velocities (and other detrimental biomechanical effects) implying that there may be optimal knee positions and range-of-motion for a given subject. The most skilled subject exhibited a high degree of consistency of knee positioning and range-of-motion. This subject adjusted for varying ball height through modified initial knee positioning while maintaining fairly constant ranges-of-motion. Key pointsInitial knee positioning and range-of-motion were positively related to racket velocity and characteristic of more skilled players for the closed stance forehand motion.Knee positioning and range-of-motion had several indirect biomechanical effects on the forehand motion such as movement of the body mass center, work of the knee, hip and back joints, and the angular range-of-motion of the hips and torso.Efforts to both increase and restrict the knee movements resulted in substantially lower racket velocities implying that there may be optimal knee positions and range-of-motion for a given subject.The most skilled subject exhibited a high degree of consistency of knee positioning and range-of-motion. This subject adjusted for varying ball height through modified initial knee positioning while maintaining fairly constant ranges-of-motion.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3763335 | PMC |
Sci Rep
January 2025
Research and Development, Aesculap AG, Tuttlingen, Germany.
In clinical movement biomechanics, kinematic measurements are collected to characterise the motion of articulating joints and investigate how different factors influence movement patterns. Representative time-series signals are calculated to encapsulate (complex and multidimensional) kinematic datasets succinctly. Exacerbated by numerous difficulties to consistently define joint coordinate frames, the influence of local frame orientation and position on the characteristics of the resultant kinematic signals has been previously proven to be a major limitation.
View Article and Find Full Text PDFSci Rep
January 2025
Chair of Applied Mechanics, Technical University of Munich, Garching, 85748, Germany.
Ankle push-off is important for efficient, human-like walking, and many prosthetic devices mimic push-off using motors or elastic elements. The knee is extended throughout the stance phase and begins to buckle just before push-off, with timing being crucial. However, the exact mechanisms behind this buckling are still unclear.
View Article and Find Full Text PDFJ Clin Orthop Trauma
February 2025
Joints and Spine Clinic, Mahavir Nagar, Kandivali West, Mumbai, 400067, India.
Introduction: Numerous orthopaedic procedures including dynamic hip screw plating and various osteotomies require placement of a reference guide pin or K wire to direct bone cuts or for drilling screw holes. Appropriate positioning of these wires is a critical component of surgery. Irrespective of whether one is a seasoned surgeon or an apprentice, these wires often need repositioning and readjustment.
View Article and Find Full Text PDFPrimates
January 2025
Laboratory of Biological Anthropology, Graduate School of Human Sciences, Osaka University, Suita, Osaka, Japan.
Gibbons, a type of lesser ape, are brachiators but also walk bipedally and without forelimb assistance, not only on the ground but also on tree branches. The arboreal bipedal walking strategy of the gibbons has been studied in previous studies in relation to two-dimensional (2D) kinematic analysis. However, because tree branches and the ground differ greatly in width, leading to a constrained foot contact point on the tree branches, gibbons must adjust their 3D joint motions of trunk and hindlimb on the tree branches.
View Article and Find Full Text PDFArthroplast Today
February 2025
Adult Reconstruction and Joint Replacement Service, Department of Orthopaedic Surgery, Hospital for Special Surgery, New York, NY, USA.
Background: Robotic arm assisted total knee arthroplasty (RA-TKA) aims to improve accuracy in bone resection, implant positioning, and joint alignment compared to manual TKA (M-TKA). However, the learning curve of RA-TKA can disrupt operating room efficiency, increase complications, and raise costs. This study examines the operative time learning curve of RA-TKA using a single robotic system.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!