The purpose of this investigation was to use a combination of image processing, force measurements and finite element modeling to calculate deformation of the knee cartilage during jumping. Professional athletes performed jumps analyzed using a force plate and high-speed video camera system. Image processing was performed on each frame of video using a color recognition algorithm. A simplified mass-spring-damper model was utilized for determination of global force and moment on the knee. Custom software for fitting the coupling characteristics was created. Simulated results were used as input data for the finite element calculation of cartilage deformation in the athlete's knee. Computer simulation data was compared with the average experimental ground reaction forces. The results show the three-dimensional mechanical deformation distribution inside the cartilage volume. A combination of the image recognition technology, force plate measurements and the finite element cartilage deformation in the knee may be used in the future as an effective noninvasive tool for prediction of injury during jumping. Key pointsEven there are many existing mathematical models of force distribution during running or jumping (Liu et al, 1998), to our knowledge there is no interdisciplinary approach where imaging processing, finite element modeling and experimental force plate system are employed.The aim is to explore noninvasive deformation in the knee cartilage during athlete's jumping on the force plate.An original image algorithms and software were developed as well as complex mathematical models using high-performance computational power of finite element modeling together with one-dimensional dynamics model.The initial results showed cartilage deformation in the knee and future research will be focused on the methodology and more precisely determination of the stress and strain distribution in the knee cartilage during training phase of sportsman.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3761555PMC

Publication Analysis

Top Keywords

finite element
20
knee cartilage
16
cartilage deformation
16
deformation knee
16
element modeling
12
force plate
12
knee
8
cartilage
8
combination image
8
image processing
8

Similar Publications

High-Performance Shear Mode Ultrasonic Transducer Operating at Ultrahigh Temperature Fabricated with BiSiO Piezoelectric Crystal.

ACS Appl Mater Interfaces

December 2024

Center for Optics Research and Engineering, State Key Laboratory of Crystal Materials, Shandong University, Qingdao 266237, China.

Shear mode ultrasonic waves are in high demand for structural health monitoring (SHM) applications owing to their nondispersive characteristics, singular mode, and minimal energy loss, especially in harsh environments. However, the generation and detection of a pure shear wave using conventional piezoelectric materials present substantial challenges because of their complex piezoelectric response, involving multiple modes. Herein, we introduce a high-quality piezoelectric crystal BiSiO (BSO), exhibiting a robust piezoelectric response ( = 45.

View Article and Find Full Text PDF

Opportunistic screening is essential to improve the identification of individuals with osteoporosis. Our group has utilized image texture features to assess bone quality using clinical MRIs. We have previously demonstrated that greater heterogeneity of MRI texture related to history of fragility fractures, lower bone density, and worse microarchitecture.

View Article and Find Full Text PDF

As a critical component of aero-engines, the processing quality of the blade has a significant impact on the engine's overall performance and service life. First, from the perspective of double abrasive grains, two finite element models-simultaneous and sequential scratches-are established. The interaction between the two abrasive grains affects not only the polishing force and chip formation but also the surface morphology of the processed workpiece.

View Article and Find Full Text PDF

This study employed numerical simulation to investigate the dynamic response characteristics of open-web girders subjected to proximity blast loading and to compare these characteristics with those of solid-web girders. The research utilized the Coupled Eulerian-Lagrangian (CEL) method for simulation, effectively combining the advantages of both Eulerian and Lagrangian approaches. This method mitigated issues related to mesh distortion while accurately modeling the damage inflicted by blast loads on the structures.

View Article and Find Full Text PDF

Residual dentin thickness and biomechanical performance of post-and-core-restored mandibular premolars: A finite element analysis study.

J Prosthet Dent

December 2024

Associate Chief Physician, Department of Prosthodontic, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, PR China. Electronic address:

Statement Of Problem: Endodontically treated teeth often require post-and-core restorations for structural support because of extensive hard tissue loss. Assessment of the effect of the residual dentin thickness on the biomechanical performance of these restorations is lacking.

Purpose: The purpose of this study was to evaluate the residual dentin thickness in mandibular premolars after post-and-core restorations using cone beam computed tomography (CBCT) and to analyze the stress distribution with finite element analysis (FEA).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!