Highly reproducible SERS detection in sequential injection analysis: real time preparation and application of photo-reduced silver substrate in a moving flow-cell.

Talanta

Institute of Chemical Technologies and Analytics, Vienna University of Technology, Getreidemarkt 9/151, A-1060 Vienna, Austria; Departement of Pharmaceutical Analytical Chemistry, Faculty of Pharmacy, Assiut University, 71526 Assiut, Egypt.

Published: November 2013

This paper reports an improved way for performing highly reproducible surface enhanced Raman scattering of different analytes using an automated flow system. The method uses a confocal Raman microscope to prepare SERS active silver spots on the window of a flow cell by photo-reduction of silver nitrate in the presence of citrate. Placement of the flow cell on an automated x and y stages of the Raman microscope allows to prepare a fresh spot for every new measurement. This procedure thus efficiently avoids any carry over effects which might result from adsorption of the analyte on the SERS active material and enables highly reproducible SERS measurements. For reproducible liquid handling the used sequential injection analysis system as well as the Raman microscope was operated by the flexible LabVIEW based software ATLAS developed in our group. Quantitative aspects were investigated using Cu(PAR)2 as a model analyte. Concentration down to 5×10(-6) M provided clear SERS spectra, a linear concentration dependence of the SERS intensities at 1333 cm(-1) was obtained from 5×10(-5) to 1×10(-3) with a correlation coefficient r=0.999. The coefficient of variation of the method Vxo was found to be 5.6% and the calculated limit of detection 1.7×10(-5) M. The results demonstrate the potential of SERS spectroscopy to be used as a molecular specific detector in aqueous flow systems.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.talanta.2013.07.059DOI Listing

Publication Analysis

Top Keywords

highly reproducible
12
raman microscope
12
reproducible sers
8
sequential injection
8
injection analysis
8
sers active
8
flow cell
8
sers
7
sers detection
4
detection sequential
4

Similar Publications

Controlling of Applied Force and Cornea Displacement Estimation in Robotic Corneal Surgery With a Gripper Surgical Instrument.

Int J Med Robot

February 2025

Faculty of Health, Education, Medicine and Social Care, Medical Technology Research Centre, The Institute of Excellence in Robotic Surgery, Anglia Ruskin University, Chelmsford, UK.

Background: The human eye consists of highly sensitive, hydrated, and relatively thin tissues, making precise control and accurate force estimation crucial in robotic eye surgery. This paper introduces a novel control method and state observer designed for a gripper surgical instrument used on the external ocular surface during robotic eye surgery.

Methods: A novel state observer, operating in tandem with the controller, estimates the applied force.

View Article and Find Full Text PDF

Sensitive and accurate determination of acetamiprid is highly desirable for guaranteeing food safety. In this Letter, an energy-transfer-based dual-mode biosensor was developed using zinc-based metal-organic frameworks (Zn-MOFs) acting as both photoelectrochemical (PEC) and electrochemiluminescent (ECL) donors and Pt@CuO cubic nanocrystals (CNs) as the energy acceptor for detecting acetamiprid. By integration of aptamer recognition with two-step DNA circuit amplification (entropy-driven DNA cycle and DNA walker), the detection of acetamiprid was converted into the assay of abundant intermediate DNA strands.

View Article and Find Full Text PDF

[Level of compliance with validation processes and analysis of measurement scales in pediatrics].

Andes Pediatr

August 2024

Facultad de Ciencias de la Empresa, Universidad Politécnica de Cartagena, Cartagena, Spain.

Unlabelled: The use of latent construct measurement scales is widespread in the medical literature. An essential condition is that the instrument be validated, in addition to being highly reliable.

Objective: To evaluate the level of compliance with various methodological and statistical premises of validation studies of psychometric instruments in pediatrics, which are necessary to ensure adequate interpretation of the results, in order to offer recommendations for future research.

View Article and Find Full Text PDF

Solvatochromic charge model of isonitrile probes for investigating hydrogen-bond dynamics with 2DIR spectroscopy.

J Chem Phys

January 2025

Department of Chemistry - Ångström Laboratory, Uppsala University, SE-75120 Uppsala, Sweden.

Isonitrile-derivatized amino acids are emerging as highly effective infrared (IR) probes for investigating the structures and dynamics of hydrogen (H)-bonds. These probes enable the quantification of chemical exchange processes in solute-solvent complexes via two-dimensional IR spectroscopy and hold significant promise for site-specific dynamic studies within proteins. Despite their potential, theoretical models that elucidate the solvatochromism of isonitriles remain underdeveloped.

View Article and Find Full Text PDF

Tooth degradation develops easily over time from initial caries to deeper cavities. The quality and durability of restorations are crucial in a patients' life, and it is primarily determined by the mechanical properties of the restorations. Clinicians and engineers apply biomimetic science in dentistry to mimic the natural design of the teeth and emphasize careful material selection as well as bond strength between the tissue and artificial material.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!