Download full-text PDF |
Source |
---|
Med Phys
January 2025
Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, Texas, USA.
Background: Diffusion-weighted (DW) turbo-spin-echo (TSE) imaging offers improved geometric fidelity compared to single-shot echo-planar-imaging (EPI). However, it suffers from low signal-to-noise ratio (SNR) and prolonged acquisition times, thereby restricting its applications in diagnosis and MRI-guided radiotherapy (MRgRT).
Purpose: To develop a joint k-b space reconstruction algorithm for concurrent reconstruction of DW-TSE images and the apparent diffusion coefficient (ADC) map with enhanced image quality and more accurate quantitative measurements.
Noise Health
January 2025
Department of Neurology, Faculty of Medicine, Ondokuz Mayis University, Samsun, Turkey.
Background: Patients with multiple sclerosis (MS) experience difficulties in understanding speech in noise despite having normal hearing.
Aim: This study aimed to determine the relationship between speech discrimination in noise (SDN) and medial olivocochlear reflex levels and to compare MS patients with a control group.
Material And Methods: Sixty participants with normal hearing, comprising 30 MS patients and 30 healthy controls, were included.
Noise Health
January 2025
Department of Internal Medicine, Faculty of Medicine, Medical Academy, Lithuanian University of Health Sciences, Kaunas, Lithuania.
Background: The effect of background noise on auscultation accuracy for different lung sound classes under standardised conditions, especially at lower to medium levels, remains largely unexplored. This article aims to evaluate the impact of three levels of Gaussian white noise (GWN) on the ability to identify three classes of lung sounds.
Methods And Materials: A pre-post pilot study assessing the impact of GWN on a group of students' ability to identify lung sounds was conducted.
Anal Chem
January 2025
College of Chemistry, Jilin Province Research Center for Engineering and Technology of Spectral Analytical Instruments, Jilin University, Qianjin Street 2699, Changchun 130012, China.
Vanin-1 is a pantetheine hydrolase that plays a key role in inflammatory diseases. Effective tools for noninvasive, real-time monitoring of Vanin-1 are lacking, largely due to background fluorescence interference in existing probes. To address this issue, we developed a dual-modal fluorescent and colorimetric probe, MB-Van1, to detect Vanin-1 with high sensitivity and selectivity.
View Article and Find Full Text PDFJ Clin Neurophysiol
December 2024
Human Brain Mapping Program, University of Pittsburgh Medical Centre, Pittsburgh, Pennsylvania, U.S.A.; and.
Objectives: Our study aimed to compare signal characteristics of subdural electrodes (SDE) and depth stereo EEG placed within a 5-mm vicinity in patients with drug-resistant epilepsy. We report how electrode design and placement collectively affect signal content from a shared source between these electrode types.
Methods: In subjects undergoing invasive intracranial EEG evaluation at a surgical epilepsy center from 2012 to 2018, stereo EEG and SDE electrode contacts placed within a 5-mm vicinity were identified.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!