A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Cotton-derived oxidized cellulose in minimally invasive thoracic surgery: a clinicopathological study. | LitMetric

Cotton-derived oxidized cellulose in minimally invasive thoracic surgery: a clinicopathological study.

Innovations (Phila)

From the *Department of General Thoracic Surgery, Katholisches Klinikum Koblenz-Montabaur, Koblenz, Germany; and †Institute of Pathology, Koblenz, Germany.

Published: June 2014

Objective: The aim of this study was to identify resorption, clinical performance, and safety of cotton-derived oxidized cellulose gauze applied as a hemostat in minimally invasive oncologic thoracic surgery.

Methods: This is a pilot prospective noncomparative observational human in vivo study. A piece of cotton-derived oxidized cellulose gauze measuring 5 × 20 cm was inserted into the subcarinal space of patients with potentially resectable lung carcinoma at the time of video-assisted mediastinoscopic lymphadenectomy and reexamined several days later for macroscopic and histologic evaluation at the time of subsequent lung resection. The primary endpoint was the local situation at the implantation site described by cellulose remnants, fluid collections, and adhesions. The secondary endpoint was safety, described by the number of adverse events and surgical reinterventions.

Results: Twenty-five consecutive eligible patients with potentially resectable lung carcinoma were included. The desired hemostatic effect was achieved in all cases. No adverse events were observed. At re-exploration 10.5 (5-28) days later, the cellulose gauze was found to lose its solid structure from the fifth day on. Remnants were last detected 14 days after insertion. The implantation site exhibited no inflammatory changes and a remarkable small amount of fluid collections and adhesions.

Conclusions: Mediastinal application of cotton-derived oxidized cellulose is safe and effective. A piece of gauze measuring 5 × 20 cm seems to be absorbed completely within 15 days, thus precluding any interference with oncologic restaging and follow-up. The absence of relevant adhesions facilitates further surgical procedures. Larger comparative confirmatory studies are required. For large-scale resorption studies, our clinical model should be translated into a porcine model.

Download full-text PDF

Source
http://dx.doi.org/10.1097/IMI.0b013e3182a6afcfDOI Listing

Publication Analysis

Top Keywords

cotton-derived oxidized
16
oxidized cellulose
16
cellulose gauze
12
minimally invasive
8
gauze measuring
8
patients resectable
8
resectable lung
8
lung carcinoma
8
implantation site
8
fluid collections
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!