We have developed a novel aza-BODIPY probe for the sensitive colorimetric detection of the nitrite ions in the aqueous medium by a simple and direct method. This probe selectively recognizes the nitrite ions through a distinct visual color change from bright blue to intense green with a sensitivity of 20 ppb. Uniquely, this probe can be coated on a glass surface to fabricate a simple solid-state dipstick device that can be used for the visual detection of the nitrite ions in the presence of other competing anions in distilled as well as natural water resources like a sea, lake, and river. Furthermore, this probe can be used for the sensitive detection of the nitrate ions when coupled to a reduction step. Our results demonstrate that this probe not only can be used for the on-site analysis and quantification but also can replace the conventional spot test carried out for the nitrite ions in the laboratory practical experiments.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1021/ac4031303 | DOI Listing |
Mikrochim Acta
January 2025
School of Material Science and Engineering, Henan University of Technology Zhengzhou, Henan, 450001, China.
A simple, fast, and cost-effective colorimetric nitrite (NO) sensor based on ZIF-67-derived CoO nanocomposite (ZCo-2 NC) structure has been developed. The prepared colorimetric sensor (ZCo-2 NC) was employed to sensitively detect NO in drinking water system by the exhibition of promising peroxidase-mimicking nanozyme-like features. The sensor manifest well-determined sensing response with excellent linear and wide range of NO sensitivity (0.
View Article and Find Full Text PDFFood Res Int
January 2025
Department of Food Engineering and Nutrition, Yellow Sea Fisheries Research Institute, Chinese Academy of Fishery Sciences, Qingdao 266071, China; Laboratory for Marine Drugs and Bioproducts, Qingdao Marine Science and Technology Center, Qingdao, Shandong 266237, China. Electronic address:
To meet the demand of consumers for high-quality dry-cured fish. This study investigates the relationship between microbial diversity and the changes in physicochemical properties and non-volatile flavor compounds of dry-cured Spanish mackerel (DCSM) throughout the curing process. Our findings demonstrate that moisture content significantly decreased during curing, while NaCl generally increased.
View Article and Find Full Text PDFInorg Chem
January 2025
Department of Chemistry and Biochemistry, University of California, Santa Barbara, California 93106, United States.
The endogenous reduction of nitrite to nitrosyl is drawing increasing attention as a protective mechanism against hypoxic injury in mammalian physiology and as an alternative source of NO, which is involved in a wide variety of biological activities. Thus, chemical mechanisms for this transformation, which are mediated by metallo proteins, are of considerable interest. The study described here examines the reactions of the biomimetic models Co(TTP)(NO) (TTP = meso-tetratolylporphyrinato dianion) and Mn(TPP)(ONO) (TPP = meso-tetraphenyl-porphyrinato dianion) in sublimated solid films with hydrogen sulfide (HS) and with ethanethiol (EtSH) at various temperatures from 77 K to room temperature using in situ infrared and optical spectroscopy.
View Article and Find Full Text PDFEnviron Monit Assess
January 2025
Department of Chemical Engineering, Faculty of Chemistry and Chemical Engineering, Babes-Bolyai University of Cluj-Napoca, 11 Arany János Street, 400028, Cluj-Napoca, Romania.
One of the leading challenges in Water Resource Recovery Facility monitoring and control is the poor data quality and sensor consistency due to the tough and complex circumstances of the process operation. This paper presents a new principal component analysis fault detection approach for the nitrate and nitrite concentration sensor based on Water Resource Recovery Facility measurements, together with the Fisher Discriminant Analysis identification of fault types. Five malfunction cases were considered: constant additive error, ramp changing error in time, incorrect amplification error, random additive error, and unchanging sensor value error.
View Article and Find Full Text PDFACS Omega
December 2024
Professor, Department of Chemistry, ANITS College, Visakhapatnam 531162, India.
In this study, we reported a novel reverse-phase UPLC method for the simultaneous estimation of nitrite and nitrate ions using a Quality by Design (QbD) approach. Nitrite and nitrate ions were separated on an ACQUITY CSH Fluoro-Phenyl column (100 × 2.1 mm, 1.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!