A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A nitinol based flexor tendon fixation device: gapping and tensile strength measurements in cadaver flexor tendon. | LitMetric

In this study, a new nitinol based fixation device was investigated for use in repairing severed digital flexor tendons. The device, composed of superelastic nitinol, is tubular in shape with inward facing tines for gripping tissue. Its cellular structure was designed such that it has a large effective Poisson's ratio, which facilitates a “finger trap” effect. This allows for reduced tendon compression during a resting state (to permit vascular perfusion) and increased compression during loading (to drive the tines into the tissue for gripping). To test the feasibility of using this device for flexor tendon repair, it was tested on cadaver flexor digitorum profundus tendons. The tendons were excised, cut in the region corresponding to a zone II laceration, and repaired using the device. The device was easy to install and did not prevent the tendon from bending. Constant strain rate tensile testing revealed a mean tensile strength of 57.6 ± 7.7 N, with a force of 53.2 ± 7.8 N at a 2 mm gap. This exceeds the suggested primary repair strength of 45 N, which has been proposed as the necessary strength for enabling early mobilization. Although considerable future studies will be needed to determine the suitability of the new repair device for clinical use, this study demonstrates the feasibility of utilizing a tubular, nitinol repair device for flexor tendon fixation.

Download full-text PDF

Source
http://dx.doi.org/10.1115/1.4025779DOI Listing

Publication Analysis

Top Keywords

flexor tendon
16
nitinol based
8
tendon fixation
8
device
8
fixation device
8
tensile strength
8
cadaver flexor
8
device flexor
8
repair device
8
flexor
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!