Fouling is a major obstacle to maintain the efficiency of ultrafiltration-based drinking water treatment process. Algal extracellular organic matters (EOMs) are currently considered as one of the major sources of membrane fouling. The objective of this study was to investigate the influence of different hydrophobic/hydrophilic fractions of EOM extracted from Microcystis aeruginosa on ultrafiltration membrane fouling at lab scale. The experimental data indicated that EOM exhibited similar flux decline trends on polyethersulfone (PES) and regenerated cellulose (RC) membranes but caused greater irreversible fouling on PES membrane than RC membrane due to its hydrophobic property. It was also observed that charged hydrophilic (CHPI) and neutral hydrophilic (NHPI) fractions caused greater flux decline over hydrophobic (HPO) and transphilic (TPI) fractions. For PES membrane, the order of the irreversible fouling potentials for the four fractions was HPO>TPI>CHPI>NHPI, while the irreversible fouling potentials of RC membrane were tiny and could be ignored. Fluorescence excitation-emission matrix (EEM) spectra and Fourier transform infrared (FTIR) spectra suggested that protein-like, polysaccharide-like and humic-like substances were the major components responsible for membrane fouling. The results also indicated that the irreversible fouling increased as the pH decreased. The addition of calcium to feed solutions led to more severe flux decline and irreversible fouling.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.scitotenv.2013.09.052DOI Listing

Publication Analysis

Top Keywords

irreversible fouling
20
membrane fouling
16
flux decline
12
fouling
10
influence hydrophobic/hydrophilic
8
hydrophobic/hydrophilic fractions
8
extracellular organic
8
organic matters
8
microcystis aeruginosa
8
aeruginosa ultrafiltration
8

Similar Publications

Low performance and the high fouling tendency of Polyetherimide (PEI) membranes prevent their widespread commercial utility. In this study, we utilized a deep eutectic solvent (DES) as a versatile agent for surface modification of the PEI membrane using a simple and sustainable method. To attain an efficient PEI membrane, modeling and optimization of the modification condition were conducted via response surface methodology (RSM).

View Article and Find Full Text PDF

This study presents the fabrication and characterization of mixed matrix membranes (MMMs) incorporating green-synthesized silver nanoparticles (AgNPs) using Hibiscus Rosa sinensis extract within a polyethersulfone (PES) matrix for nanofiltration (NF) application. The membranes were evaluated for their pure water permeability, salt rejection, dye removal, and antifouling performance. Results showed that the membrane with 0.

View Article and Find Full Text PDF

Mitigation of irreversible membrane biofouling by CNTs-PVDF conductive composite membrane.

Environ Res

December 2024

School of Environmental Science and Engineering, Tiangong University, State Key Laboratory of Separation Membranes and Membrane Processes, Binshui West Road 399, Xiqing District, Tianjin, 300387, PR China; Cangzhou Institute of Tiangong University, Cangzhou 061000, China. Electronic address:

Biofouling has been one of the major challenges impacting the long-term stable operation of ultrafiltration processes. Irreversible biofouling is considerably more harmful than reversible biofouling. Conductive membrane, as a new technology to effectively mitigate membrane fouling, lack research of controlling irreversible biofouling.

View Article and Find Full Text PDF

Construction of Photothermal Intelligent Membranes for Point-of-Use Water Treatment.

Molecules

December 2024

MOE Key Laboratory of Deep Earth Science and Engineering, College of Architecture & Environmental Engineering, Sichuan University, Chengdu 610065, China.

For the removal of waterborne pathogens in remote areas and disaster emergency situations, point-source water treatment methods are more suitable. Photothermal sterilization is ideal for point-of-use (POU) systems, as it effectively eliminates pathogens without secondary pollution or bacterial resistance issues. By combining photothermal with membrane treatment, these membranes rapidly heat up under near-infrared (NIR) light, enabling both bacterial retention and sterilization.

View Article and Find Full Text PDF

Interaction mechanisms between fouling and chemical cleaning on the ageing behavior of ion-exchange membranes during electrodialysis treatment of flue gas desulfurization wastewater.

Water Res

March 2025

Shanghai Engineering Research Center of Energy - Saving in Heat Exchange Systems, College of Environmental and Chemical Engineering, Shanghai University of Electric Power, Shanghai 200090, China. Electronic address:

Article Synopsis
  • Chemically irreversible fouling (CIF) and chemical erosion significantly affect the performance and properties of ion-exchange membranes (IEMs) used in desalination, leading to a phenomenon known as membrane ageing.
  • The ageing process consists of three stages where desalination rates initially decrease, then increase, and finally decline again, largely influenced by contaminants like anionic polyacrylamide (APAM) and calcium sulfate (CaSO).
  • CIF limits cleaning efficiency and alters membrane structure, while chemical erosion damages functional groups and the polymer matrix, affecting key attributes like ion exchange capacity and mechanical strength, thus ultimately influencing the membranes' fouling behaviors.
View Article and Find Full Text PDF