A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fluoroscopic guide to an ideal implant position for Sapien XT and CoreValve during a valve-in-valve procedure. | LitMetric

Objectives: This study sought to provide a guide to the fluoroscopic appearances of various valve-in-valve (VIV) combinations by deploying a transcatheter heart valve (THV) within a degenerated surgical heart valve (SHV) in an ideal position.

Background: VIV procedures are being increasingly performed with substantial experience acquired in treating degenerated SHV in the aortic position with Sapien/Sapien XT (Edwards Lifesciences Ltd., Irvine, California) and CoreValve/Evolute (Medtronic Inc., Minneapolis, Minnesota) valves. Although less invasive than conventional surgery, securing the THV in an optimal position within the SHV determines the success of this novel treatment.

Methods: For VIV implantation, we selected appropriate Sapien XT and CoreValve/Evolute sizes depending on the internal diameter of the SHV. Implantation was performed in vitro. In case of the Sapien XT valve, it was deployed 4 to 5 mm below the sewing ring of the SHV, whereas the CoreValve/Evolute was deployed 5 mm below the level of the sewing ring. Photographs and fluoroscopic images of the various VIV combinations were obtained in side profile to study the ideal position and end-on profile to study the circularity of the THV.

Results: Fluoroscopic images obtained in side profile highlighted the differences in various VIV combinations, as all SHV are unique in their fluoroscopic appearances. Also, all THV implants in various VIV combinations achieved a nearly circular shape.

Conclusions: To achieve an optimal result when considering VIV, it is important to be familiar with the structure and fluoroscopic appearances of the failed SHV, the THV used, and their combination.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcin.2013.05.020DOI Listing

Publication Analysis

Top Keywords

viv combinations
16
fluoroscopic appearances
12
heart valve
8
sewing ring
8
fluoroscopic images
8
side profile
8
profile study
8
viv
7
shv
7
fluoroscopic
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!