A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

In vivo measurement of human achilles tendon morphology using freehand 3-D ultrasound. | LitMetric

In vivo measurement of human achilles tendon morphology using freehand 3-D ultrasound.

Ultrasound Med Biol

School of Rehabilitation Sciences and Centre for Musculoskeletal Research, Griffith Health Institute, Griffith University, Southport, Queensland, Australia. Electronic address:

Published: January 2014

This study investigated the accuracy of phantom volume and length measurements and the reliability of in vivo Achilles tendon (AT) volume, length and cross-sectional area measurements obtained using freehand 3-D ultrasound. Participants (n = 13) were scanned on consecutive days under active and passive loading conditions. In vivo AT length was evaluated using a two-point method and an approach that accounted for AT curvature (centroid method). Three-dimensional ultrasound provided accurate measures of phantom volume and length (mean difference = 0.05 mL and 0.2 mm, respectively) and reliable in vivo measures of AT volume, length and average cross-sectional area, with all intra-class correlations coefficients greater than 0.98. The mean minimally detectable changes for in vivo AT volume, two-point length and centroid length were 0.2 mL, 1.5 mm and 2.0 mm, respectively. Two-point AT length underestimated centroid AT length by 0.7 mm, suggesting that the effect of curvature on in vivo AT length is negligible.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultrasmedbio.2013.08.009DOI Listing

Publication Analysis

Top Keywords

volume length
16
length
10
achilles tendon
8
freehand 3-d
8
3-d ultrasound
8
phantom volume
8
cross-sectional area
8
in vivo length
8
two-point length
8
centroid length
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!