Background: Flexion-extension radiographs are often used to assess for removal of the cervical collar in the setting of trauma. The objective of this study was to evaluate their adequacy. We hypothesized that a significant proportion is inadequate.

Methods: This was a retrospective review of C-spine clearance at a level 1 trauma center. A trauma-trained radiologist interpreted all flexion-extension radiographs for adequacy. Studies performed within 7 days of injury were considered acute.

Results: Three hundred fifty-five flexion-extension radiographs were examined. Ninety-five percent% of these studies were inadequate (51% because of the inability to visualize the top of T1, whereas 44% had less than 30° of angulation from neutral). Two hundred ten studies were performed acutely; of these, 97% were inadequate. When performed 7 days or longer from injury, 91% were inadequate.

Conclusions: Injury to the C-spine may harbor significant consequences; therefore, its proper evaluation is critical. The majority of flexion-extension films are inadequate. As such, they should not be included in the algorithm for removal of the cervical collar. If used, adequacy must be verified and supplemental radiographic studies obtained as indicated.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjsurg.2013.09.001DOI Listing

Publication Analysis

Top Keywords

flexion-extension radiographs
12
setting trauma
8
removal cervical
8
cervical collar
8
studies performed
8
performed days
8
futility flexion-extension
4
flexion-extension c-spine
4
c-spine films
4
films setting
4

Similar Publications

Objective: Spinal fusion is a commonly performed surgical procedure used to relieve pain, deformity, and instability of various spinal pathologies. Although there have been attempts to standardize spinal fusion assessment radiologically, there is currently no unified definition that also considers clinical symptomology. This review attempts to create a more holistic and standardized definition of spinal fusion.

View Article and Find Full Text PDF

Background: There has been an increasing interest in elbow hemiarthroplasty to circumvent the problems with total elbow arthroplasty for comminuted distal humerus fractures in the elderly. The primary aim of the study is to assess the mid-term clinical and radiological outcomes of patients undergoing TEA and hemiarthroplasty for distal humerus fractures.

Methods: Retrospective analysis of data for patients undergoing hemiarthroplasty for distal humerus fractures (OTA- C3 Comminuted total articular fractures) was done.

View Article and Find Full Text PDF

Anterior cruciate ligament reconstruction aims to improve knee stability and range of motion. The AperFix system consists of polymer components, and fixed-loop fixation is an established endoscopic technique. Our aim in this study was to compare the long-term clinical and radiological results of AperFix and fixed-loop fixation and to prove that the long-term results of the AperFix fixation method are at least as good as those of the fixed loop device.

View Article and Find Full Text PDF

The effect of cervical spine flexion-extension motion on odontoid parameters.

J Orthop Surg Res

January 2025

Department of Spine Surgery, The First Affiliated Hospital of Guangxi Medical University, 6 Shuangyong Road, Guangxi Zhuang Autonomous Region, Nanning, 530021, China.

Objective: To assess the stability of odontoid parameters on flexion-extension motion and to validate the accuracy of the physiological cervical lordosis (CL) predictive formula across different cervical positions.

Methods: Standard cervical spine lateral radiographs in neutral, flexion, and extension positions were collected to measure odontoid incidence (OI), odontoid tilt (OT), C2 slope (C2S), CL, T1 slope (T1S), and T1S minus CL (T1S-CL). Friedman's test was used to assess the differences in parameters among the three cervical spine positions.

View Article and Find Full Text PDF

Cortical windows for implant and cement removal during revision total elbow arthroplasty.

JSES Int

November 2024

Division of Hand and Upper-Extremity Surgery, Department of Orthopaedic Surgery, Geisinger Commonwealth School of Medicine, Geisinger MSKI, Danville, PA, USA.

Background: Revision total elbow arthroplasty (rTEA) remains a technically challenging procedure with potential for substantial morbidity. Cases involving excessively long cement mantles, removal of well-fixed implants or infected revisions requiring complete cement removal introduce additional technical challenges. Our purpose was to describe the outcomes, results, and complications associated with the use of cortical windows in rTEA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!