A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mammotome biopsy system for the resection of breast lesions: Clinical experience in two high-volume teaching hospitals. | LitMetric

Ultrasound-guided vacuum-assisted breast biopsy (VABB) is regarded as a feasible, effective, minimally invasive and safe method for the removal of benign breast lesions, without the occurrence of serious complications. The aim of this study was to evaluate the feasibility, efficacy and safety of ultrasound-guided VABB using the Mammotome biopsy system in the treatment of breast lesions. The clinical outcomes of 3,681 patients with breast lesions were evaluated following excisions by ultrasound-guided VABB in two high-volume teaching hospitals. From January 2008 to December 2012, a total of 4,867 ultrasound-guided VABB procedures were performed in the 3,681 patients, who had a mean age of 37.8 years (range, 16-73 years). The parameters examined in this analysis included lesion size, lesion location in the inner breast, Breast Imaging Reporting and Data System (BI-RADS) ultrasound category and histopathological diagnosis. Ultrasonography follow-up was performed at 3-6 month intervals in order to assess recurrence. The size of the investigated lesions ranged between 6 and 62 mm and a histopathological diagnosis was made in 100% of cases. The results indicated that the majority of specimens (98.89%) were benign. On average, the ultrasound-guided VABB was performed in 10.3 min (range, 7.5-43 min) and the mean number of cores removed in the procedure was 8.1 (range, 3-32). A complete excision was achieved in the majority of cases (99.7%). The presence of a hematoma was the most common complication following the biopsy, and was observed in 27.5% of patients. The mean follow-up period was 25.5 months (range, 1-60 months), during which the rate of recurrence was 4.4%. The results indicated that ultrasound-guided VABB using the Mammotome biopsy system is an effective and safe procedure that is able to rapidly remove the majority of benign breast lesions using a small incision and without the occurrence of scarring or complications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3786805PMC
http://dx.doi.org/10.3892/etm.2013.1191DOI Listing

Publication Analysis

Top Keywords

breast lesions
20
ultrasound-guided vabb
20
mammotome biopsy
12
biopsy system
12
breast
8
lesions clinical
8
high-volume teaching
8
teaching hospitals
8
benign breast
8
vabb mammotome
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!