Bortezomib enhances fatty liver preservation in Institut George Lopez-1 solution through adenosine monophosphate activated protein kinase and Akt/mTOR pathways.

J Pharm Pharmacol

Experimental Pathology Department, IIBB-CSIC, Centro de Investigación Biomédica en Red de Enfermedades Hepáticas y Digestivas (CIBEREHD), IDIBAPS, Barcelona, Catalonia, Spain.

Published: January 2014

Objectives: The aim of this study is to investigate the protective mechanisms induced by bortezomib added to Institut George Lopez (IGL)-1 preservation solution to protect steatotic livers against cold ischaemia reperfusion injury and to examine whether these mechanisms occur through the activation of adenosine monophosphate activated protein kinase (AMPK), Akt/mTOR pathways.

Methods: Steatotic livers from obese rats were preserved for 24 h (at 4 °C) in IGL-1 solution with or without bortezomib (100 nM) or pretreated with AMPK inhibitor adenine 9-α-D-arabinofuranoside and preserved in IGL-1 + bortezomib. Livers were then perfused for 2 h at 37 °C. Liver injury (alanine aminotransferase/aspartate aminotransferase) and function (bile production and vascular resistance) were measured. Also, Akt/mTOR, phosphorylated AMPK (pAMPK) and apoptosis were determined by Western blot analyses.

Key Findings: Bortezomib addition to IGL-1 solution significantly reduced steatotic liver injury, improved graft function and decreased liver apoptosis. These benefits were diminished by the pretreatment of obese rats with AMPK inhibitor Ara. Western blot analyses showed a significant increase in pAMPK after ischaemia and reperfusion. We also observed a significant phosphorylation of Akt in IGL-1 +bortezomib group that, in turn, induced the phosphorylation of mTOR and glycogen synthase kinase 3β.

Conclusions: Bortezomib, at low and non toxic concentration, is a promising additive to IGL-1 solution for steatotic liver preservation. Its protective effect is due to the activation of AMPK and Akt/mTOR pathways.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jphp.12154DOI Listing

Publication Analysis

Top Keywords

igl-1 solution
12
liver preservation
8
institut george
8
adenosine monophosphate
8
monophosphate activated
8
activated protein
8
protein kinase
8
akt/mtor pathways
8
steatotic livers
8
ischaemia reperfusion
8

Similar Publications

Background: Liver transplantation (LT) is the best treatment for end-stage liver disease; however, biliary complications (BCs) still pose a significant challenge. Among the post-transplant BC, strictures and biliary fistulas are the most common. Biliary strictures are classified as anastomotic and non-anastomotic.

View Article and Find Full Text PDF

Background and Objectives: StoreProtect Plus® is a preserving solution for cold organ storage, with a composition identical to Institute Georges Lopez (IGL-1) solution. The aim of this single center study was to compare the clinical performance of StoreProtect Plus with the generic counterpart of University of Wisconsin preservation fluid, named SPS-1®. Materials and Methods: The clinical outcomes of 168 consecutive organs preserved with StoreProtect Plus solution and 167 organs preserved with SPS-1 solution were compared.

View Article and Find Full Text PDF

Attenuating the rheological and structural consequences of intestinal ischemia-reperfusion-injury (IRI) is important in transplant proceedings. Preconditioning is an often-proposed remedy. This technique uses physical or pharmacological methods to manipulate key ischemia pathways, such as oxidation, inflammation, and autophagy, prior to ischemia.

View Article and Find Full Text PDF

Current Trends in Organ Preservation Solutions for Pancreas Transplantation: A Single-Center Retrospective Study.

Transpl Int

April 2022

Hepatobiliopancreatic Surgery and Liver and Pancreatic Transplantation Unit, Clinic Institute of Digestive and Metabolic Diseases (ICMDiM), Hospital Clínic, University of Barcelona, Barcelona, Spain.

Due to the high vulnerability of the pancreas to ischemia-reperfusion injury, choices regarding preservation solution markedly affect pancreas transplant success. A retrospective single-center analysis of 380 pancreas transplants (2000-2019) was performed to correlate current preservation solutions with transplant outcomes. Early graft failure requiring transplantectomy within 30 days post-transplant occurred in 7.

View Article and Find Full Text PDF

The total damage inflicted on the liver before transplantation is associated with several surgical manipulations, such as organ recovery, washout of the graft, cold conservation in organ preservation solutions (UW, Celsior, HTK, IGL-1), and rinsing of the organ before implantation. Polyethylene glycol 35 (PEG35) is the oncotic agent present in the IGL-1 solution, which is an alternative to UW and Celsior solutions in liver clinical transplantation. In a model of cold preservation in rats (4 °C; 24 h), we evaluated the effects induced by PEG35 on detoxifying enzymes and nitric oxide, comparing IGL-1 to IGL-0 (which is the same as IGL-1 without PEG).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!