We have recently demonstrated a means for quantifying the absorption and scattering properties of biological tissue through multidiameter single-fiber reflectance (MDSFR) spectroscopy. These measurements can be used to correct single-fiber fluorescence (SFF) spectra for the influence of optical properties, enabling quantification of intrinsic fluorescence. In our previous work, we have used a series of pinholes to show that selective illumination and light collection using a coherent fiber bundle can simulate a single solid-core optical fiber with variable diameter for the purposes of MDSFR spectroscopy. Here, we describe the construction and validation of a clinical MDSFR/SFF spectroscopy system that avoids the limitations encountered with pinholes and free-space optics. During one measurement, the new system acquires reflectance spectra at the effective diameters of 200, 600, and 1000 μm, and a fluorescence spectrum at an effective diameter of 1000 μm. From these spectra, we measure the absolute absorption coefficient, μ(a), reduced scattering coefficient, μ'(s'), phase function parameter, γ, and intrinsic fluorescence, Qμ(a,x)(f), across the measured spectrum. We validate the system using Intralipid- and polystyrene sphere-based scattering phantoms, with and without the addition of the absorber Evans Blue. Finally, we demonstrate the combined MDSFR/SFF of phantoms with varying concentrations of Intralipid and fluorescein, wherein the scattering properties are measured by MDSFR and used to correct the SFF spectrum for accurate quantification of Qμ(a,x)(f).

Download full-text PDF

Source
http://dx.doi.org/10.1117/1.JBO.18.10.107005DOI Listing

Publication Analysis

Top Keywords

multidiameter single-fiber
8
single-fiber reflectance
8
fiber bundle
8
scattering properties
8
mdsfr spectroscopy
8
intrinsic fluorescence
8
1000 μm
8
fluorescence
5
method rapid
4
rapid multidiameter
4

Similar Publications

Purpose: Achieving endocrine remission by gross total resection is challenging in pituitary neuroendocrine tumours (PitNETs) with cavernous sinus invasion. This study aims to assess the safety, feasibility, and optimal dose for intraoperative fluorescence imaging as an added instrument to discriminate PitNET from surrounding tissue using bevacizumab-800CW, targeting vascular endothelial growth factor A (VEGF-A).

Methods: In part I, dose-escalation (0-4∙5-10-25 mg) was performed in 4 groups of 3 patients with PitNETs Knosp grade 3-4.

View Article and Find Full Text PDF

Esophageal adenocarcinoma causes 6% of cancer-related deaths worldwide. Near-infrared fluorescence molecular endoscopy (NIR-FME) uses a tracer that targets overexpressed proteins. In this study, we aimed to investigate the feasibility of an epidermal growth factor receptor (EGFR)-targeted tracer, cetuximab-800CW, to improve detection of early-stage esophageal adenocarcinoma.

View Article and Find Full Text PDF

Significance: The combination of reflectance and fluorescence spectroscopy allows the determination of tissue optical properties and the calculation of the intrinsic fluorescence in vivo. These parameters can discriminate between tissues and may allow the discrimination of malignant from benign tissue. While this approach has significant clinical potential, the lack of standardization and quality assessment prevents the upscaling of research.

View Article and Find Full Text PDF

Experimental validation of a recently developed model for single-fiber reflectance spectroscopy.

J Biomed Opt

February 2021

University of Amsterdam, Amsterdam UMC, Cancer Center Amsterdam, Amsterdam Cardiovascular Sciences,, The Netherlands.

Significance: We recently developed a model for the reflectance measured with (multi-diameter) single-fiber reflectance (SFR) spectroscopy as a function of the reduced scattering coefficient μs', the absorption coefficient μa, and the phase function parameter psb. We validated this model with simulations.

Aim: We validate our model experimentally.

View Article and Find Full Text PDF

Patients with Barrett's esophagus are at an increased risk to develop esophageal cancer and, therefore, undergo regular endoscopic surveillance. Early detection of neoplasia enables endoscopic treatment, which improves outcomes. However, early Barrett's neoplasia is easily missed during endoscopic surveillance.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!