Lightweight bilayer barium sulfate-bismuth oxide composite thyroid collars for superior radiation protection in fluoroscopy-guided interventions: a prospective randomized controlled trial.

Radiology

From the Department of Vascular and Interventional Radiology, Baptist Cardiac and Vascular Institute, 8900 N Kendall Dr, Miami, FL 33176 (H.U., M.J.B., B.T.K., C.P., R.G., M.S.); and Department of Angiology, University Hospital Basel, Basel, Switzerland (H.U., D.S.).

Published: February 2014

Purpose: To test whether newer bilayer barium sulfate-bismuth oxide composite (XPF) thyroid collars (TCs) provide superior radiation protection and comfort during fluoroscopy-guided interventions compared with standard 0.5-mm lead-equivalent TCs.

Materials And Methods: Institutional review board approval and written informed consent were obtained for this HIPAA-compliant study, and 144 fluoroscopy-guided vascular interventions were included at one center between October 2011 and July 2012, with up to two operators randomly assigned to wear XPF (n = 135) or standard 0.5-mm lead-equivalent (n = 121) TCs. Radiation doses were measured by using dosimeters placed outside and underneath the TCs. Wearing comfort was assessed at the end of each procedure on a visual analog scale (0-100, with 100 indicating optimal comfort). Adjusted differences in comfort and radiation dose reductions were calculated by using a mixed logistic regression model and the common method of inverse variance weighting, respectively.

Results: Patient (height, weight, and body mass index) and procedure (type and duration of intervention, operator, fluoroscopy time, dose-area product, and air kerma) data did not differ between the XPF and standard groups. Comfort was assessed in all 256 measurements. On average, the XPF TCs were 47.6% lighter than the standard TCs (mean weight ± standard deviation, 133 g ± 14 vs 254 g ± 44; P < .001) and had a significantly higher likelihood of a high level of comfort (visual analog scale >90; odds ratio, 7.6; 95% confidence interval: 3.0, 19.2; P < .001). Radiation dose reduction provided by the TCs was analyzed in 117 data sets (60 in the XPF group, 57 in the standard group). The mean radiation dose reductions (ie, radiation protection) provided by XPF and standard TCs were 90.7% and 72.4%, with an adjusted mean difference of 17.9% (95% confidence interval: 7.7%, 28.1%; P < .001) favoring XPF.

Conclusion: XPF TCs are a lightweight alternative to standard 0.5-mm lead-equivalent TCs and provide superior radiation protection during fluoroscopy-guided interventions.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiol.13122834DOI Listing

Publication Analysis

Top Keywords

radiation protection
16
superior radiation
12
fluoroscopy-guided interventions
12
standard 05-mm
12
05-mm lead-equivalent
12
radiation dose
12
tcs
9
bilayer barium
8
barium sulfate-bismuth
8
sulfate-bismuth oxide
8

Similar Publications

Lifetime Risks for Lung Cancer due to Occupational Radon Exposure: A Systematic Analysis of Estimation Components.

Radiat Res

January 2025

Federal Office for Radiation Protection, Ingolstädter Landstrasse 1, 85764 Neuherberg, Germany.

Lifetime risk estimates play a key role in many areas of radiation research. Here, the focus is on the lifetime excess absolute risk (LEAR) for dying from lung cancer due to occupational radon exposure based on uranium miners cohort studies. The major components in estimating LEAR were systematically varied to investigate the variability and uncertainties of results.

View Article and Find Full Text PDF

Background: Radiotherapy as a complement or an alternative to neurosurgery has a central role in the treatment of skull base grade I-II meningiomas. Radiotherapy techniques have improved considerably over the last two decades, becoming more effective and sparing more and more the healthy tissue surrounding the tumour. Currently, hypo-fractionated stereotactic radiotherapy (SRT) for small tumours and normo-fractionated intensity-modulated radiotherapy (IMRT) or proton-therapy (PT) for larger tumours are the most widely used techniques.

View Article and Find Full Text PDF

Objective: Assess the level of radiation-related knowledge (RRK) and nuclear energy-related knowledge (NERK) among residents near the Sanmen Nuclear Power Plant, the first project adopted the Advanced Passive Pressurized Water Reactor (AP1000) technology.

Methods: In this study, respondents were selected using stratified multi-stage random sampling for residents aged 18 years and above living within 30 kilometers of the Sanmen Nuclear Power Station. Respondents were surveyed face-to-face by investigators who received standardized training.

View Article and Find Full Text PDF

Background: Different doses of radiotherapy (RT) exert diverse effects on tumor immunity, although the precise irradiation method remains unknown. This study sought to elucidate the influence of combining different doses of RT with immune checkpoint inhibitors (ICIs) on the infiltration of CD8T cells within tumors, thereby augmenting the anti-tumor response.

Methods: Constructing a mouse model featuring bilateral lung cancer tumors subjected to high and low dose irradiation, the analysis of RNA transcriptome sequencing data and immunohistochemical validation for tumors exposed to various dosages guided the selection of the optimal low-dose irradiation scheme.

View Article and Find Full Text PDF

A preliminary study of linear accelerator-based spatially fractionated radiotherapy.

Front Oncol

January 2025

Department of Radiation Oncology, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.

Purpose: This study aimed to provide quantitative information for implementing Lattice radiotherapy (LRT) using a medical linear accelerator equipped with the Millennium 120 multi-leaf collimator (MLC). The research systematically evaluated the impact of varying vertex diameters and separations on dose distribution, peak-to-valley dose ratio (PVDR), and normal tissue dose.

Methods: A cylindrical Virtual Water™ phantom was used to create LRT treatments using the Eclipse version 16.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!