Background: There is always a need to assess whether small changes in bracket prescription can lead to visually detectable differences in tooth positions. However, with little clinical evidence to show advantages of any of the popularly used bracket systems, orthodontists are forced to make clinical decisions with little scientific guidance.

Aim: To compare the orthodontic cases finished with Roth and MBT prescription using American Board of Orthodontics-Objective Grading System (ABO-OGS).

Settings And Design: Department of Orthodontics, Post-graduate dental college, retrospective cross-sectional study.

Materials And Methods: Forty patients selected were divided into two groups of 20 patients each finished with straight wire appliance using Roth and MBT prescription, respectively. The examiner ability was assessed and calibrated by one of the ABO certified clinician to grade cases using the OGS.

Statistical Analysis: Unpaired student t-test was used and P < 0.05 was accepted as significant.

Results And Conclusions: MBT bracket group had a lower score of 2.60 points in buccolingual inclination and lower score of 1.10 points in occlusal contact category that was statistically significant when compared with Roth group. The difference in total ABO-OGS score was 2.65 points showing that the outcome for the MBT prescription was better than that of the Roth prescription, which is statistically significant, but with little or no clinical significance. It can be concluded that use of either one of the Roth and MBT bracket prescriptions have no impact to the overall clinical outcome and quality of treatment entirely depends on clinician judgment and experience.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3793550PMC
http://dx.doi.org/10.4103/0976-237X.118361DOI Listing

Publication Analysis

Top Keywords

roth mbt
16
mbt bracket
12
mbt prescription
12
bracket prescription
8
prescription american
8
american board
8
grading system
8
lower score
8
roth
6
mbt
6

Similar Publications

Introduction: The objective of this study was to evaluate the influence of orthodontic bracket prescription on smile attractiveness.

Methods: Three women were chosen according to their sagittal skeletal pattern: skeletal Class I, II, or III malocclusion. For each, 3 smiling pictures were taken in frontal, oblique, and lateral views.

View Article and Find Full Text PDF

Introduction: Generalized anxiety disorder (GAD) is a common psychiatric disorder that can cause significant functional impairment to a patient's life. Mind body therapies (MBT) have increasingly been used as an intervention to manage symptoms of anxiety. Heart rate variability (HRV) biofeedback is a specific MBT that utilizes real-time feedback on autonomic functioning to train the physiological stress response through diaphragmatic breathing.

View Article and Find Full Text PDF

Do orthodontists aim to decrease the duration of fixed appliance treatment?

J Orthod Sci

February 2021

Department of Orthodontic, College of Dentistry, Baghdad University, Baghdad, Iraq.

Objectives: The aim of the present study was to investigate the trends in the use of fixed appliance and accelerated orthodontics to decrease the treatment duration. Further, this study aimed to assess the effect of demographic factors on the participant's choice of treatment modality.

Methods: This was a cross-sectional study in the form of questionnaire-based online survey especially designed and distributed to 265 orthodontists via email.

View Article and Find Full Text PDF

Objective: To investigate and compare the slot sizes and parallelism of metal injection molding (MIM) and computerized numerical control (CNC) brackets.

Methods: The following four MIM bracket series with 0.022-inch (in) slots were selected for investigation: Di MIM mini Twin (Ortho Organizers), Mini Diamond Roth (Ormco), Gemini MBT (3M Unitek), and Formula R Roth (Tomy).

View Article and Find Full Text PDF

Background: Torque is an important component of preadjusted edgewise prescriptions to achieve ideal/optimum tooth position and more so in aesthetics sensitive maxillary anterior teeth. Thus, the need to audit available commercial brands of 018Roth and 022MBT was felt and in vitro analysis of eight brands namely 3M Unitek, Dentaurum, d-tech, IMD Medical, Libral Leone, Modern Orthodontics, Ormco and Ortho Organizer, was carried out.

Methods: The method involved perfect superimposition of two standardized images: one delineating facial axis of the tooth with stainless steel straight wire and other with full dimension arch wire engagement in bracket.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!