Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Three-dimensional digital subtraction angiography (3D-DSA) is a modern technique that allows for better appreciation of complex vascular lesions. This study evaluates the impact of various dose reduction strategies on 3D-DSA image quality.
Methods: The standard manufacturer 5 s 0.36 μGy/frame setting was modified to create lower dose 3D-DSA protocols by varying the acquisition time (5 or 3 s) and/or dose per frame (0.36, 0.24, 0.17, and 0.10 μGy/f). All protocols were evaluated in three swine. Four raters measured a segment of the external carotid artery on two-dimensional multiplanar reconstruction images. The raters were also presented with three-dimensional volume rendered images from all protocols in a blinded manner and asked to choose the superior image. A full model analysis of variance with repeated measure factors was performed to compare mean differences in measurements between protocols.
Results: Measurement differences between the standard and low dose protocols were not clinically significant (<0.5 mm). All raters demonstrated high inter-rater reliability. The 5 s protocols were considered as qualitatively superior to the 3 s protocols. Delivered system doses ranged from 43.8 to 6.5 mGy. The 5 s 0.10 μGy/frame protocols generated 65-68% less delivered dose compared with the 5 s 0.36 μGy/frame setting.
Conclusions: Low dose 3D-DSA protocols with preserved image quality are achievable, and can help reduce unnecessary radiation exposure to both patients and operators. The 5 s low dose protocols generated clinically acceptable and superior images compared with the 3 s protocols, suggesting a more important role for acquisition time than dose per frame to maintain image quality.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1136/neurintsurg-2013-010914 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!