Objectives: To establish the nature and extent of femur sagittal bowing by determining outer and inner anterior cortex geometries and sizes using analytical 3-dimensional computed tomography modeling and relate the resultant femoral curvature with the curvatures of available intramedullary nails.
Methods: Computed tomography scans were rendered in 3D using modeling software to reconstruct 2 geometries: (1) outer cortex and (2) medullary canal. Femoral bow in the sagittal plane and the anterior cortical thickness were measured. Three curvature points were selected on both the geometries. Exterior anterior cortex radius of curvature (AROC) and medullary canal radius of curvature (MROC) were compared within and between each femur pair.
Results: Three groups of femurs exhibiting significantly different geometry patterns emerged: (1) AROC significantly greater than MROC, (2) AROC equivalent to MROC, and (3) AROC significantly smaller than MROC. Anterior cortical thickness ranged from 2.2 to 7.0 mm was significantly different for males versus females, and it varied inversely with age.
Conclusions: The study confirms that the radius of curvature of most intramedullary nails exceeds the sagittal radius of curvature of most adult femurs (both AROC and MROC). An intramedullary nail selected based on the anterior curvature would impinge on the anterior cortices at the proximal and distal anterior aspects of the femur in specimens with AROC > MROC. Conversely, in specimens with AROC < MROC, an intramedullary nail selected based on the anterior curvature would impinge on the proximal and distal posterior cortices. That cortical thickness varied significantly in accordance with gender and age is also relevant to surgical planning. MROC, in addition to the AROC alone, should be one of several design parameters used to match specific intramedullary nail design to an individual patient.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BOT.0000000000000019 | DOI Listing |
Odontology
January 2025
Department of General Surgery and Medical-Surgical Specialties, University of Catania, 95123, Catania, Italy.
The aim of this study was to assess the cyclic fatigue resistance of a single-file system (i.e., Hyflex EDM OneFile), during continuous rotation and reflex dynamic motion with and without irrigation.
View Article and Find Full Text PDFSensors (Basel)
December 2024
Sauvage Laboratory for Smart Materials, Shenzhen Key Laboratory of Flexible Printed Electronics Technology, Harbin Institute of Technology, Shenzhen 518055, China.
Electronic skin is widely employed in multiple applications such as health monitoring, robot tactile perception, and bionic prosthetics. In this study, we fabricated millimeter-scale electronic skin featuring compact sensing units using the Boston Micro Fabrication S130 (a high-precision additive manufacturing device) and the template removal method. We used a gallium-based liquid metal and achieved an inner channel diameter of 0.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Electrical Engineering, Faculty of Science and Technology, University Al Azhar Indonesia, Jakarta, Indonesia.
Curvature of a dielectric waveguide always leads to attenuation of the mode power as it propagates through the curved region. In single mode guides, bending loss becomes significant as the radius of curvature reduces and is strongly dependent on the confinement of the guided mode, so that weakly guiding waveguides can tolerate only large radii of curvature. In this paper we verify our new theoretical version on power loss prediction of S-bend optical waveguides by using analytical theory based on integration of absorption coefficient and compare it to the experimental measurement of such waveguide bends.
View Article and Find Full Text PDFComplement Med Res
January 2025
Eye Hospital, China Academy of Chinese Medical Sciences, Beijing, China.
Background: The increasing prevalence of myopia among Chinese children and adolescents, especially at younger ages, has emerged as a significant concern in recent years. Pre-myopia is a key period for myopia prevention and control in children and adolescents. Previous studies suggested auricular acupressure (AA) therapy might offer a viable approach to prevent and slow down myopia progression.
View Article and Find Full Text PDFMicromachines (Basel)
November 2024
Center for Precision Engineering, Harbin Institute of Technology, Harbin 150001, China.
Over the past 30 years, researchers have developed X-ray-focusing telescopes by employing the principle of total reflection in thin metal films. The Wolter-I focusing mirror with variable-curvature surfaces demands high precision. However, there has been limited investigation into the removal mechanisms for variable-curvature X-ray mandrels, which are crucial for achieving the desired surface roughness and form accuracy, especially in reducing mid-spatial frequency (MSF) errors.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!