Objective: To evaluate clinical effects of computer aided design and computer aided manufacturing (CAD/CAM) milled zirconia crown in three aspects: aesthetic, contact wear and fracture.
Methods: Sixty patients were divided into two groups.In one group, 35 full contour CAD/CAM zirconia crown were made on molars of 30 patients. The manufacturing process of zirconia crown was as follow. First, the three dimensional(3-D) data of working models, antagonist impression and check records were acquired by 3-D laser scanning Dental wings S50. Then full contour zirconia crowns, which had functional occlusal contacts with antagonistic teeth, and appropriate contact with adjacent teeth were designed with Zeno-CAD(V4.2.5.5.12919) software. ZENOSTAR Zr pure zirconia material was milled in digital controlled machine WIELAND 4030 M1.In the end, the zirconia crown were completed with the method of second sintering and polishing. After clinical try-in, the crown was cemented.In the control group, thirty gold alloy full crown were made and cemented on molars of 30 patients. According to the modified U S Public Health Service Criteria(USPHS) evaluation standard, all crowns were evaluated on the same day, at three months, half a year, one year and two years following delivery. There were three aspects we were focusing on in the evaluation: aesthetic, contact wear(restoration and antagonist), and fracture.
Results: In all the prosthesis we evaluated during the 24 months, no fracture was found. Contact wear of crowns varies according to different antagonist teeth.
Conclusions: The zirconia crowns show privilege in aesthesis, toughness and anti-wearing.However, there is contact wear on antagonistic natural teeth. Thus it is a good choice when full zirconia crowns are indicated on two antagonistic teeth in both jaws.
Download full-text PDF |
Source |
---|
Sci Rep
December 2024
Computer Aided Drug Designing and Molecular Modeling Lab, Department of Bioinformatics, Alagappa University, Karaikudi, 630 003, Tamil Nadu, India.
Phthalic acid esters are pivotal plasticizers in various applications, including cosmetics, packaging materials, and medical devices. They have garnered significant attention from the scientific community due to their persistence in ecosystems. The multifaceted aspects of PAEs, encompassing leaching, transformation, and toxicity, underscore their prominence as primary components of anthropogenic waste.
View Article and Find Full Text PDFSci Rep
December 2024
Wireless@VT, Bradley Department of Electrical and Computer Engineering, Virginia Tech, Blacksburg, 24061, VA, USA.
Owing to the ability of reconfigurable intelligent surfaces (RISs) to control the propagation environment in their vicinity, they have emerged as an appealing solution to enhance the performance of next-generation wireless networks. While the effectiveness of RISs with complete channel state information (CSI) is well-documented, their performance with limited user information remains less explored. This is particularly pronounced when an RIS interferes with nodes in a potentially non-cooperating network, making CSI acquisition challenging.
View Article and Find Full Text PDFJ Prosthet Dent
December 2024
Associate Chief Physician, Department of Prosthodontic, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Clinical Research Center for Oral Diseases of Zhejiang Province, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Engineering Research Center of Oral Biomaterials and Devices of Zhejiang Province, Hangzhou, PR China. Electronic address:
Statement Of Problem: Endodontically treated teeth often require post-and-core restorations for structural support because of extensive hard tissue loss. Assessment of the effect of the residual dentin thickness on the biomechanical performance of these restorations is lacking.
Purpose: The purpose of this study was to evaluate the residual dentin thickness in mandibular premolars after post-and-core restorations using cone beam computed tomography (CBCT) and to analyze the stress distribution with finite element analysis (FEA).
AJNR Am J Neuroradiol
December 2024
From the UCLA Brain Tumor Imaging Laboratory (BTIL), Center for Computer Vision and Imaging Biomarkers (S.O., A.K., B.M.E., J.Y.), University of California, Los Angeles, Los Angeles, California
Background And Purpose: Precise and individualized targeting of the ventral intermediate thalamic nucleus for the MR-guided focused ultrasound is crucial for enhancing treatment efficacy and avoiding undesirable side effects. In this study, we tested the hypothesis that the spatial relationships between Thalamus Optimized Multi Atlas Segmentation derived segmentations and the post-focused ultrasound lesion can predict post-operative side effects in patients treated with MR-guided focused ultrasound.
Materials And Methods: We retrospectively analyzed 30 patients (essential tremor, n = 26; tremor-dominant Parkinson's disease, n = 4) who underwent unilateral ventral intermediate thalamic nucleus focused ultrasound treatment.
Am J Otolaryngol
December 2024
Department of Otorhinolaryngology Head and Neck Surgery, Tianjin First Central Hospital, Tianjin 300192, China; Institute of Otolaryngology of Tianjin, Tianjin, China; Key Laboratory of Auditory Speech and Balance Medicine, Tianjin, China; Key Clinical Discipline of Tianjin (Otolaryngology), Tianjin, China; Otolaryngology Clinical Quality Control Centre, Tianjin, China.
Purpose: To use deep learning technology to design and implement a model that can automatically classify laryngoscope images and assist doctors in diagnosing laryngeal diseases.
Materials And Methods: The experiment was based on 3057 images (normal, glottic cancer, granuloma, Reinke's Edema, vocal cord cyst, leukoplakia, nodules and polyps) from the dataset Laryngoscope8. A classification model based on deep neural networks was developed and tested.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!