A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Investigation of the synergistic effect with amino acid-derived chiral ionic liquids as additives for enantiomeric separation in capillary electrophoresis. | LitMetric

Recently, chiral ionic liquids (ILs) have drawn more and more attention in chiral separation by capillary electrophoresis (CE). In this paper, two chiral ILs based on amino acid derivatives, L-alanine and L-valine tert butyl ester bis (trifluoromethane) sulfonimide, were applied for the first time in CE to evaluate their potential synergistic effects with classical chiral selectors (β-cyclodextrin derivatives) for enantiomeric separation. As observed, improved separation of tested drug enantiomers was obtained with the presence of chiral ILs compared to the conventional β-cyclodextrin derivatives separation system. Parameters such as type and proportion of organic modifier, type and concentration of chiral ILs, concentration of chiral selector, buffer pH and applied voltage were systematically investigated with Me-β-CD/chiral ILs as model system to optimize the novel synergistic system, and the best results were obtained when 15 mM chiral ILs were introduced into the 30 mM sodium citrate/citric acid (20% organic modifier included) buffer solution containing 20 mM Me-β-CD at pH 5.0 with a 20 kV applied voltage for naproxen, pranoprofen and warfarin.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.chroma.2013.09.064DOI Listing

Publication Analysis

Top Keywords

chiral ils
16
chiral
9
chiral ionic
8
ionic liquids
8
enantiomeric separation
8
separation capillary
8
capillary electrophoresis
8
β-cyclodextrin derivatives
8
organic modifier
8
concentration chiral
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!