Validation of a novel translumbar ultrasound technique for measuring renal dimensions in horses.

Vet Radiol Ultrasound

School of Veterinary Medicine and Science, University of Nottingham, Sutton Bonington Campus, Sutton Bonington, Leicestershire, LE12 5RD, UK.

Published: January 2015

A reliable method for obtaining renal ultrasonographic measurements in the horse is important for diagnosis and monitoring of clinical renal disease. The aims of this prospective study were to develop and validate a novel translumbar ultrasound technique for measuring renal dimensions in horses. Six Thoroughbred or Thoroughbred part bred horses were recruited. All horses were scheduled for euthanasia due to reasons unrelated to the kidneys. Two observers recorded renal length, width, and depth; and dimensions of the cortex, medulla, pyramids, and pelvis for both kidneys in each horse using novel translumbar and conventional transabdominal ultrasound methods. The same measurements were recorded from post-mortem renal specimens. Both kidneys were consistently identified by both methods in the 15-17th intercostal spaces and paralumbar fossa. Using the translumbar technique, maximal dimensions were obtained for the left kidney in the 16th intercostal space (length 16.2 ± 2.0 cm, width 11.8 ± 0.5 cm, depth 6.4 ± 0.9 cm) and for the right kidney in the 15th intercostal space (length 16.1 ± 1.2 cm, width 13.4 ± 1.2 cm, depth 6.7 ± 0.7 cm). Renal dimensions obtained by transabdominal and translumbar projections did not differ (P > 0.05). Good correlations were found between overall renal dimensions and post-mortem measurements for both ultrasound techniques (r(2) > 0.8), but were better for the translumbar method (mean r(2) = 0.92 cf. 0.88). Good-to-excellent reliability was found for all translumbar ultrasound measurements except for the renal cortex. Reproducibility was better for the larger (overall length, width, and depth) than the smaller (cortex, medulla, and pyramids) structures. Findings indicated that translumbar ultrasonography is a valid method for measuring renal dimensions in horses.

Download full-text PDF

Source
http://dx.doi.org/10.1111/vru.12112DOI Listing

Publication Analysis

Top Keywords

renal dimensions
20
novel translumbar
12
translumbar ultrasound
12
measuring renal
12
dimensions horses
12
renal
10
translumbar
8
ultrasound technique
8
technique measuring
8
length width
8

Similar Publications

Introduction: In recent years, numerous hospitals have established in-house three-dimensional (3D) printing centers, enabling health-care facilities to leverage the transformative capabilities of additive manufacturing technology on their premises. With this emerging opportunity arises a necessity to undertake a thorough assessment of the manufactured tools employed in clinical practice. The objectives of this article are to describe the pathway of in-house printing and evaluate the accuracy of 3D-printed specific instruments.

View Article and Find Full Text PDF

Patients with end-stage kidney disease (ESRD) represent a high-risk population in terms of both development of and death by cardiovascular diseases. Outcome data of ESRD patients with severe aortic valve stenosis (AS) treated by transcatheter aortic valve implantation (AVI) are scarce. We aim to compare the outcome of ESRD patients undergoing transfemoral (TF) or transapical (TA) AVI.

View Article and Find Full Text PDF

Background: Giant hydronephrosis as an rare condition is often caused by chronic ureteral obstruction. Nephroplication is a crucial procedure to improve urinary drainage in the kidney-sparing surgery for patients with giant hydronephrosis. However, traditional nephroplication via suturing kidney has technical difficulty and many potential risks.

View Article and Find Full Text PDF

Background And Aims: An arterial aneurysm is characterized by a localized expansion of a blood vessel relative to its original dimensions. Specifically, an abdominal aortic aneurysm (AAA) is identified as an aortic diameter measuring at least one and a half times the standard diameter at the renal artery level, approximately equivalent to 2.0 cm.

View Article and Find Full Text PDF

Systolic Blood Pressure and Pulse Pressure in Heart Failure: Pooled Participant-Level Analysis of 4 Trials.

J Am Coll Cardiol

November 2024

Division of Cardiovascular Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA. Electronic address:

Background: Hypertension is common in patients with heart failure with mildly reduced or preserved ejection fraction (HFmrEF/HFpEF), and current guidelines recommend treating systolic blood pressure (SBP) to a target <130 mm Hg. However, data supporting treatment to this target are limited. Additionally, pulse pressure (PP), a marker of aortic stiffness, has been associated with increased risk of cardiovascular events, but its prognostic impact in HFpEF has not been extensively studied.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!