Purpose: To assess if fully automated localization of the aorta can be achieved using phase contrast (PC) MR images.

Materials And Methods: PC cardiac-gated MR images were obtained as part of a large population-based study. A fully automated process using the Hough transform was developed to localize the ascending aorta (AAo) and descending aorta (DAo). The study was designed to validate this technique by determining: (i) its performance in localizing the AAo and DAo; (ii) its accuracy in generating AAo flow volume and DAo flow volume; and (iii) its robustness on studies with pathological abnormalities or imaging artifacts.

Results: The algorithm was applied successfully on 1884 participants. In the randomly selected 50-study validation set, linear regression shows an excellent correlation between the automated (A) and manual (M) methods for AAo flow (r = 0.99) and DAo flow (r = 0.99). Bland-Altman difference analysis demonstrates strong agreement with minimal bias for: AAo flow (mean difference [A-M] = 0.47 ± 2.53 mL), and DAo flow (mean difference [A-M] = 1.74 ± 2.47 mL).

Conclusion: A robust fully automated tool to localize the aorta and provide flow volume measurements on phase contrast MRI was validated on a large population-based study.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3969872PMC
http://dx.doi.org/10.1002/jmri.24338DOI Listing

Publication Analysis

Top Keywords

fully automated
16
aao flow
12
flow volume
12
dao flow
12
automated tool
8
flow
8
phase contrast
8
large population-based
8
population-based study
8
flow 099
8

Similar Publications

Background: The National Lung Screening Trial (NLST) has shown that screening with low dose CT in high-risk population was associated with reduction in lung cancer mortality. These patients are also at high risk of coronary artery disease, and we used deep learning model to automatically detect, quantify and perform risk categorisation of coronary artery calcification score (CACS) from non-ECG gated Chest CT scans.

Materials And Methods: Automated calcium quantification was performed using a neural network based on Mask regions with convolutional neural networks (R-CNN) for multiorgan segmentation.

View Article and Find Full Text PDF

Integrated SegFlow, µSIA, and UPLC for Online Sialic Acid Quantitation of Glycoproteins Directly from Bioreactors.

Eng Life Sci

January 2025

Analytical Development & Analytical Attribute Science in Biologics Bristol Myers Squibb Devens Massachusetts USA.

This study emphasizes the critical importance of closely monitoring and controlling the sialic acid content in therapeutic glycoproteins, including EPO, interferon-γ, Orencia, Enbrel, and others, as the level of sialylation directly impacts their pharmacokinetics (PK), immunogenicity, potency, and overall clinical performance due to its influence on protein clearance via hepatic asialoglycoprotein receptors (ASGPR). The ASGPR recognizes and binds to glycoproteins exposed to terminal galactose or N-acetylgalactosamine residues, leading to receptor-mediated endocytosis. Recent studies have demonstrated that sialylation of O-linked glycan plays a role in protecting against macrophage galactose lectin (MGL)-mediated clearance.

View Article and Find Full Text PDF

Semi-automated vs fully automated surveillance for non-ventilator hospital-acquired pneumonia: going for the gold when bronze is all there is.

Clin Microbiol Infect

January 2025

Department of Population Medicine, Harvard Medical School and Harvard Pilgrim Health Care Institute, Boston, Massachusetts; Department of Medicine, Brigham and Women's Hospital, Boston, Massachusetts. Electronic address:

View Article and Find Full Text PDF

This study explored the evolving landscape of Microphysiological Systems (MPS), with a focus on organoids and organ-on-a-chip (OoC) technologies, which are promising alternatives to animal testing in drug discovery. MPS technology offers in vitro models with high physiological relevance, simulating organ function for pharmacokinetic studies. Organoids composed of 3D cell aggregates and OoCs mimicking in vivo environments based on microfluidic platforms represent the forefront of MPS.

View Article and Find Full Text PDF

Purpose: Using a fully automated multitask deep learning method, which enabled simultaneous segmentation and quantification of all major anterior segment structures with swept-source optical coherence tomography (SS-OCT), we aimed to investigate the three-dimensional (3D) alterations in iris morphology before and after implantable collamer lens (ICL) surgery.

Methods: All enrolled patients underwent anterior segment SS-OCT (ANTERION) within one week before and after ICL surgery. A multitask network automatically performed iris SS-OCT image segmentation and quantitative measurements of 3D iris morphology (iris thickness and volume of the inner 1-mm annular area and the outer 1-2-mm annular area, iris curvature [I-Curve], and iris smooth index [SI]).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!