A variant of gradient elution moving boundary electrophoresis with channel current detection is described, which uses relatively long channels (1.5 cm) for separation and detection. The signal for each analyte is determined to have the shape of a parabola ending with a break in slope. The capabilities of the new method are demonstrated for separation and quantitation of ATP and ADP, a measurement relevant for high-throughput screening assays. The results indicate that the new method is capable of reproducibly measuring the ratio of ADP concentration to ATP plus ADP concentration with an analysis time of less than 2 min and with a 1 SD uncertainty of 0.018 (over a range of 0-1).

Download full-text PDF

Source
http://dx.doi.org/10.1002/elps.201300253DOI Listing

Publication Analysis

Top Keywords

gradient elution
8
elution moving
8
moving boundary
8
boundary electrophoresis
8
electrophoresis channel
8
channel current
8
current detection
8
atp adp
8
adp concentration
8
detection long
4

Similar Publications

Size exclusion chromatography-gradient (SEC-Gradient) is a powerful technique to separate polymers by their chemical composition. The stationary phase is first conditioned with a gradient from adsorli to desorli, and polymer samples are injected after the gradient in SEC conditions. Since its first description in 2011 by Schollenberger and Radke, it has never been applied to block copolymers.

View Article and Find Full Text PDF

A Simple and Sensitive LC-MS/MS Method for the Determination of Mobocertinib and Its Metabolite Desmethyl-Mobocertinib in Human Plasma and Its Application to Clinical Pharmacokinetic Study.

Biomed Chromatogr

February 2025

Yangzhou University Medical College, Jiangsu Key Laboratory of Experimental & Translational Non-coding RNA Research, Institute of Translational Medicine, Yangzhou University, Yangzhou, Jiangsu Province, China.

Mobocertinib is a potent selective tyrosine kinase inhibitor approved for the treatment of non-small cell lung cancer with activating EGFR exon 20 insertions. The aim of this study was to develop a procedure for liquid chromatography tandem mass spectrometry (LC-MS/MS) for the determination of mobocertinib and its metabolite desmethyl-mobocertinib in human plasma. The human plasma samples were precipitated with acetonitrile and analyzed using a Waters ACQUITY BEH C column coupled to a triple quadrupole mass spectrometer.

View Article and Find Full Text PDF

Liquid Chromatography Combined With Tandem Mass Spectrometry for the Pharmacokinetic and Metabolism Studies of PROTAC ARV-471 in Rats.

Biomed Chromatogr

February 2025

Department of Breast and Thyroid Surgery, The First Affiliated Hospital of University of Science and Technology of China, Anhui Provincial Hospital, Hefei, Anhui Province, China.

Proteolysis targeting chimera (PROTAC) is emerging as a promising medicinal modality, which has aroused widespread interest among the field of pharmaceutical manufacturing in the recent years. ARV-471 is an orally active PROTAC estrogen receptor degrader against breast cancer, which leads to the ubiquitylation and subsequent degradation of estrogen receptors via the proteasome. In this study, we developed a highly sensitive liquid chromatography tandem mass spectrometry method (LLOQ = 0.

View Article and Find Full Text PDF

Dichloroacetic acid (DCAA), trichloroacetic acid (TCAA), and bromate (BrO) are disinfection byproducts (DBPs) formed during drinking water treatment and pose health risks. Rapid and reliable detection of these DBPs is essential for ensuring water safety. Non-suppressed ion chromatography (IC)-electrospray ionization mass spectrometry (IC-ESI-MS/MS) offers a promising approach for simultaneous analysis of organic haloacetic acids (HAAs) and inorganic oxyhalides, but previous methods using toxic methylamine can pose health risks.

View Article and Find Full Text PDF

In this study, we extended a previously developed one-pot double derivatization reaction to establish the first routine isotope-coded multiplex derivatization for vitamin D and its metabolites for application in clinical environments, using commercial reagents, without the need for specialized reagents and advanced synthesis requirements. The original derivatization process consisted of using both a Cookson-type reagent and derivatization of hydroxyl groups. Initially, the analytes are derivatized by a Diels-Alder reaction using 4-phenyl-1,2,4-triazoline-3,5-dione (PTAD), followed by acetylation using acetic anhydride, catalyzed by 4-dimethylaminopyridine at room temperature.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!