A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Programming implantable cardioverter-defibrillators in patients with primary prevention indication to prolong time to first shock: results from the PROVIDE study. | LitMetric

Background: Shock therapy delivery by implantable cardioverter-defibrillators (ICD) can be painful and may have adverse consequences. Reducing shock burden for patients with ICDs would be beneficial.

Methods: PROVIDE was a prospective, randomized study of primary prevention ICD patients. Patients in the experimental group received a combination of programmed parameters with higher detection rates, longer detection intervals, empiric antitachycardia pacing (ATP), and optimized supraventricular tachycardia (SVT) discriminators, while those in the control group were programmed with conventional parameters. Shock therapy and arrhythmic syncope were compared.

Results: Of 1,670 patients enrolled (846 in the experimental group, 824 in the control group) and monitored over a follow-up of 530 ± 241 days, 202 patients received shock therapy for any cause (82 in the experimental group and 120 in the control group). The median time to first shock was significantly prolonged (13.1 vs 7.8 months, hazard ratio [HR]: 0.62, 95% confidence interval [CI]: 0.47 to 0.82, P = 0.0005) and the 2-year shock rate significantly reduced (12.4% vs 19.4%, P < 0.001) in the experimental group compared to the control group. There was no increase in arrhythmic syncope (HR: 1.64, 95% CI: 0.69 to 3.90, P = 0.26), while the overall mortality was reduced (HR: 0.7, 95% CI: 0.50 to 0.98, P = 0.036) in the experimental group compared to the control group.

Conclusion: A combination of programmed parameters utilizing higher detection rate, longer detection intervals, empiric ATP, and optimized SVT discriminators reduced ICD therapies without increasing arrhythmic syncope and was associated with reduction in all-cause mortality among ICD patients.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jce.12273DOI Listing

Publication Analysis

Top Keywords

experimental group
20
control group
16
shock therapy
12
arrhythmic syncope
12
group
9
implantable cardioverter-defibrillators
8
primary prevention
8
time shock
8
icd patients
8
combination programmed
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!