A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of 3-D ultrasound system for assessment of adolescent idiopathic scoliosis (AIS): and system validation. | LitMetric

Adolescent idiopathic scoliosis (AIS) is a common spinal disease and the prevalence of AIS is 2 to 4 % of the youngsters in the United States. Radiograph based Cobb's method is regarded as the gold standard. AIS patients normally have to undergo regular X-ray assessment every 4 to 6 months until skeletal maturity is reached. Because of radiation hazard, X-ray images cannot be taken frequently, and thus it is difficult to perform close monitoring for the disease progression and treatment outcomes. In this study, a free-hand 3D ultrasound imaging system has been successfully developed for the radiation-free assessment of AIS. A series of B-mode ultrasound images with their spatial information were exploited to form a spine model for measuring the spine curvature. Sixteen spine phantoms with different simulated deformity were scanned by both conventional X-ray imaging and the 3D ultrasound system. The results showed that there was a strong correlation (R(2) = 0.759) between the Cobb's angles obtained by the two methods. The results also demonstrated a very good intra- and inter-observer reproducibility with ICC of 0.99 and 0.89, repectively. The findings suggest that it is feasible to use 3D ultrasound imaging for the assessment of scoliosis and deserves further clinical tests on patients with spine deformity.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2013.6611037DOI Listing

Publication Analysis

Top Keywords

ultrasound system
8
adolescent idiopathic
8
idiopathic scoliosis
8
scoliosis ais
8
ultrasound imaging
8
ultrasound
5
ais
5
development 3-d
4
3-d ultrasound
4
system
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!