The shape of the oscillometric envelope is known to affect the accuracy of automatic noninvasive blood pressure (NIBP) measurement devices that use the oscillometric principle to determine systolic and diastolic blood pressures. This study proposes a novel shape classification method that uses data mining techniques to determine the characteristic sequences for different envelope shapes. The results indicate that the proposed method effectively determines the characteristic sequences for different subject groups. Subjects in the high- score group and in the low- score group tend to have an envelope with a broader plateau and are bell-shaped, respectively. This information about shape can be used for future determination of the correct algorithm for systolic and diastolic blood pressures determination in NIBP devices.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/EMBC.2013.6610871 | DOI Listing |
J Hypertens
July 2024
Faculty of Medicine, Health and Human Sciences, Macquarie University.
There is little quantitative clinical data available to support blood pressure measurement accuracy during cuff inflation. In this study of 35 male and 5 female lightly anaesthetized subjects aged 64.1 ± 9.
View Article and Find Full Text PDFBlood Press Monit
August 2024
Department of Medicine, University of Alberta.
Objective: Understanding of how oscillometric waveforms (OMW) vary between pregnant and nonpregnant individuals remains low. An exploratory analysis was completed to assess for quantitative and qualitative changes in OMW and oscillometric envelope features in pregnancy.
Design And Methods: Eighteen pregnant individuals (over 20 weeks gestational age) and healthy, nonpregnant (HNP) women were recruited.
J Hum Hypertens
January 2024
CSIR-National Physical Laboratory, Dr. K. S. Krishnan Marg, New Delhi, 110012, India.
An oscillometric waveform (OMW) envelope-based blood pressure (BP) monitoring device is widely used to monitor blood pressure and prevent hypertension and adverse cardiovascular events. At present, all primary care physicians and clinicians widely recommend oscillometric-based BP devices. The consumer selects the device based on their own decision, without knowing whether the device is validated or not, resulting in over- or under-treatment of hypertension.
View Article and Find Full Text PDFPhysiol Meas
December 2022
Research Centre of Intelligent Healthcare, Faculty of Health and Life Science, Coventry University, Coventry CV1 5FB, United Kingdom.
The oscillometric blood pressure (BP) measurement technique estimates BPs from analyzing the oscillometric cuff pressure waveform (oscillogram) envelope. The oscillogram envelope maximum is associated with physiological changes and influences BP measurement accuracy. We aim to quantitatively investigate the effect of BP and aging on the changes of oscillogram envelope maximum.
View Article and Find Full Text PDFJ Hypertens
November 2021
Research Centre of Intelligent Healthcare, Faculty of Health and Life Science, Coventry University, Coventry, UK.
Background: The oscillometric blood pressure (BP) measurement technique estimates BPs from analyzing the envelop of oscillometric cuff pressure waveform. The oscillometric waveform envelope shape is associated with physiological changes and influences BP measurement accuracy. The aim of this study was to comprehensively quantify BP- and age-related changes of oscillometric waveform envelope characteristics.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!