The aim of this study is to develop a three-dimensional touch interface for mobile devices, specifically a touch interface for detecting fingertip force. This interface consists of a conventional touch interface and an electromyogram (EMG) amplifier. The fingertip force during manipulation of the touch interface is estimated from the EMG measurement. We develop a method for obtaining fingertip force information using an EMG, while the two-dimensional position of the finger is measured using the conventional touch interface found in mobile devices. Further, we evaluate the validity of our newly developed interface by comparing the fingertip force estimated using our proposed method with the fingertip force measured using a force sensor. Lastly, we develop an application using our interface.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2013.6610282DOI Listing

Publication Analysis

Top Keywords

touch interface
24
fingertip force
24
interface
8
interface mobile
8
mobile devices
8
conventional touch
8
force
7
touch
6
fingertip
6
interface sensing
4

Similar Publications

The advancements in cardiovascular imaging over the past two decades have been significant. The miniaturization of ultrasound devices has greatly contributed to their widespread adoption in operating rooms and intensive care units. The integration of AI-enabled tools has further transformed the field by simplifying echocardiographic evaluations and enhancing the reproducibility of hemodynamic measurements, even for less experienced operators.

View Article and Find Full Text PDF

Magneto-responsiveness in living organisms, exemplified by migratory birds navigating vast distances, offers inspiration for soft robots and human-computer interfaces. However, achieving both high magneto-responsiveness and resilient mechanical properties in synthetic materials has been challenging. Here, we develop magneto-iono-elastomers (MINEs), combining exceptional magnetization [2.

View Article and Find Full Text PDF

Capacitive pressure sensors based on bioinspired structured electrode for human-machine interaction applications.

Biosens Bioelectron

March 2025

Key Laboratory of Bionic Engineering (Ministry of Education), Jilin University, Changchun, Jilin, 130022, China; The National Key Laboratory of Automotive Chassis Integration and Bionics (ACIB), College of Biological and Agricultural Engineering, Jilin University, Changchun, 130022, China; Institute of Structured and Architected Materials, Liaoning Academy of Materials, Shenyang, 110167, China.

Flexible pressure sensor is a crucial component of tactile sensors and plays an integral role in numerous significant fields. Despite the considerable effort put forth, how to further improve sensitivity with ingenious yet easy-to-manufacture structures and apply them to emerging fields such as structure/materials recognition, human motion monitoring, and human-machine interaction remains a challenge. Here, we develop a highly sensitive flexible capacitive pressure sensor featuring a structured electrode layer with embedded microcracks and a dielectric layer with micro-convex structures, which are combined with an iontronic interface.

View Article and Find Full Text PDF

Intracortical microstimulation (ICMS) is a method for restoring sensation to people with paralysis as part of a bidirectional brain-computer interface (BCI) to restore upper limb function. Evoking tactile sensations of the hand through ICMS requires precise targeting of implanted electrodes. Here we describe the presurgical imaging procedures used to generate functional maps of the hand area of the somatosensory cortex and subsequent planning that guided the implantation of intracortical microelectrode arrays.

View Article and Find Full Text PDF

Background: This research aims to improve the control of assistive devices for individuals with hemiparesis after stroke by providing intuitive and proportional motor control. Stroke is the leading cause of disability in the United States, with 80% of stroke-related disability coming in the form of hemiparesis, presented as weakness or paresis on half of the body. Current assistive exoskeletonscontrolled via electromyography do not allow for fine force regulation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!