We designed and tested a new rollable and implantable medical device to directly and continuously measure intraocular pressure. Since high intraocular pressure is a leading risk factor for glaucoma, such a system could solve the difficulties encountered in the management of this condition. In fact, glaucoma is one among those pathologies that could most benefit of an adaptive patient-specific medicine device. The presented prototype was realized with standard industrial microelectronic technologies (Flip-Chip on Kapton flexible PCB) and off-the-shelf IC components. Detailed system description and measurements, obtained during in-vitro and laboratory characterizations, are reported.

Download full-text PDF

Source
http://dx.doi.org/10.1109/EMBC.2013.6610221DOI Listing

Publication Analysis

Top Keywords

intraocular pressure
12
rollable implantable
8
implantable intraocular
4
pressure sensor
4
sensor continuous
4
continuous adaptive
4
adaptive management
4
management glaucoma
4
glaucoma designed
4
designed tested
4

Similar Publications

Background: Uveitis is a rare ocular adverse reaction of zoledronic acid, the specific clinical features are not clarified. This study was to investigate the clinical features of zoledronic acid-induced uveitis and provide reference for rational use of zoledronic acid.

Methods: We collected clinical data on zoledronic acid-induced uveitis for retrospective analysis by searching Chinese and English data up to October 31, 2024.

View Article and Find Full Text PDF

Minimally invasive glaucoma surgeries (MIGS) offer an alternative approach, aiming to be both safe and effective. Defined by their ab interno technique, which avoids creating a bleb, MIGS procedures seek to reduce intraocular pressure (IOP) by enhancing the outflow pathways of aqueous humor. Techniques include stenting, incisions, and excisions of the trabecular meshwork, canaloplasty of Schlemm's canal, and drainage implants that enhance uveoscleral outflow to the subchoroidal space.

View Article and Find Full Text PDF

To investigate macula and optic nerve head (ONH) mitochondrial metabolic activity using flavoprotein fluorescence (FPF) in normal, glaucoma suspect (GS), and open-angle glaucoma (OAG) eyes we performed a cross-sectional, observational study of FPF in normal, GS, and OAG eyes. The macula and ONH of each eye was scanned and analyzed with a commercially available FPF measuring device (OcuMet Beacon, OcuSciences Inc., Ann Arbor, MI).

View Article and Find Full Text PDF

Purpose: To investigate the effect of average intraocular pressure (IOP) on the true rate of glaucoma progression (RoP) in the United Kingdom Glaucoma Treatment Study (UKGTS).

Methods: UKGTS participants were randomized to placebo or Latanoprost drops and monitored for up to two years with visual field tests (VF, 24-2 SITA standard), IOP measurements, and optic nerve imaging. We included eyes with at least three structural or functional assessments (VF with <15% false-positive errors).

View Article and Find Full Text PDF

Introduction: In the era of functional intraocular lens (IOL) implantation, it is crucial to investigate the influence of different capsulorhexis sizes (including the diameter of the capsulorhexis, area of the anterior capsule opening, anterior capsule coverage, centration and circularity of the capsulorhexis) on the postoperative outcomes (eg, visual acuity, capsule shrinkage, IOL stability and intraocular pressure) in patients undergoing cataract surgery. This is particularly important in patients with high myopia or diabetes mellitus. The proposed protocol aims to enhance the transparency of our research and offer references for future studies.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!