The present control method used in our helical flow total artificial heart (HFTAH) would only need four parameters. Nowadays, gauge pressure sensors are being used to obtain the pressure needed for control parameters. Nevertheless, there are also many following problems such as calibration, maintenance, offset drift and infection due to the skin-penetrative lines for the usage of gauge pressure sensor. Therefore, it is preferable to find another substitutional way instead of the gauge sensor to measure the pressure. In addition, with an eye to completing an implantable HFTAH, we would like to do without any lines through the experiment animal. Therefore, it was confirmed in this study that whether there is a relation between the left atrial pressure (LAP) and its pulse pressure (amplitude). Subsequently the mean value of LAP and its amplitude were quantified. There are two methods used in this study to process the data. Method one, frequency spectrum analysis, is to quantify the signals by getting the absolute value of amplitude for a fixed heartbeat analysis. Method two, by using the synchronous detection method, it is postulated to be more applicable to variant heartbeat data with 1/R control. By the relation of LAP and the pulse pressure acquired in the above two methods, as long as the amplitude of LAP is known by the absolute pressure sensor, it's able to obtain the mean value of LAP (for it suggests a linear relation). Therefore the characteristic could substitute one of the control parameter (that is the LAP), and the other three parameters will be acquired by estimation thus it doesn't need to measure them additionally. Consequently, it is expected that acquiring LAP by absolute pressure sensor for one of the control parameters could attain to an implantable HFTAH.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1109/EMBC.2013.6609589 | DOI Listing |
Cardiovasc Eng Technol
January 2025
Institute for Medical Engineering and Science, Massachusetts Institute of Technology, MA, Cambridge, USA.
Purpose: Atrial fibrillation (AF) is the most common chronic cardiac arrhythmia that increases the risk of stroke, primarily due to thrombus formation in the left atrial appendage (LAA). Left atrial appendage occlusion (LAAO) devices offer an alternative to oral anticoagulation for stroke prevention. However, the complex and variable anatomy of the LAA presents significant challenges to device design and deployment.
View Article and Find Full Text PDFPediatr Nephrol
January 2025
Department of Anesthesiology, West China Hospital, Sichuan University, No. 37 Guoxue Lane, Wuhou District, Chengdu, 610000, Sichuan, China.
Background: Cardiac surgery-associated acute kidney injury (CSA-AKI) is a notably common complication in pediatrics, with an incidence rate ranging from 15 to 64%. This rate is significantly higher than that observed in adults. Currently, there is a lack of substantial evidence regarding the association between intraoperative blood pressure variability (BPV) during cardiac surgery with cardiopulmonary bypass (CPB) and the development of AKI in pediatric patients.
View Article and Find Full Text PDFArch Gynecol Obstet
January 2025
Faculty of Medicine and Health Sciences, Tel Aviv University, Tel Aviv, Israel.
Purpose: To quantify the separation between maternal blood cell-free (cf)DNA markers in preeclampsia and unaffected pregnancies and compare with existing markers. This approach has not been used in previous studies.
Methods: Comprehensive systematic literature search of PubMed to identify studies measuring total cfDNA, fetal cf(f)DNA or the fetal fraction (FF) in pregnant women.
Surg Endosc
January 2025
Clinica Chirurgica, Department of Experimental and Clinical Medicine, Section of Surgical Sciences, Polytechnic University of Marche, Ancona, Italy.
Introduction: Altered vascular microcirculation is recognized as a risk factor for anastomotic leakage (AL) in colorectal surgery. However, few studies evaluated its impact on AL using different devices, with heterogeneous results. The present study reported the initial experience measuring gut microcirculatory density and flow with the aid of incidence dark-field (IDF) videomicroscopy (Cytocam, Braedius, Amsterdam, The Netherlands) comparing its operative outcome using a propensity score matching (PSM) model based on age, gender, and Charlson Comorbidity Index (CCI).
View Article and Find Full Text PDFSci Rep
January 2025
Renal Division, Department of Medicine, Universidade Federal de São Paulo, Rua Pedro de Toledo, 781, São Paulo, SP, 04039-032, Brazil.
Partial stenosis of the renal artery causes renovascular hypertension (RVH) and is accompanied by chronic renal ischemia, resulting in irreversible kidney damage. Revascularization constitutes the most efficient therapy for normalizing blood pressure (BP) and has significant benefits for renal function; however, the tissue damage caused by chronic hypoxia is not fully reversed. Mesenchymal stem cells (MSCs) have produced discrete results in minimizing RVH and renal tissue and functional improvements since the obstruction persists.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!