Physiological noise in brainstem FMRI.

Front Hum Neurosci

Clinical Research and Imaging Centre, University of Bristol, Bristol , UK.

Published: October 2013

The brainstem is directly involved in controlling blood pressure, respiration, sleep/wake cycles, pain modulation, motor, and cardiac output. As such it is of significant basic science and clinical interest. However, the brainstem's location close to major arteries and adjacent pulsatile cerebrospinal fluid filled spaces, means that it is difficult to reliably record functional magnetic resonance imaging (fMRI) data from. These physiological sources of noise generate time varying signals in fMRI data, which if left uncorrected can obscure signals of interest. In this Methods Article we will provide a practical introduction to the techniques used to correct for the presence of physiological noise in time series fMRI data. Techniques based on independent measurement of the cardiac and respiratory cycles, such as retrospective image correction (RETROICOR, Glover et al., 2000), will be described and their application and limitations discussed. The impact of a physiological noise model, implemented in the framework of the general linear model, on resting fMRI data acquired at 3 and 7 T is presented. Data driven approaches based such as independent component analysis (ICA) are described. MR acquisition strategies that attempt to either minimize the influence of physiological fluctuations on recorded fMRI data, or provide additional information to correct for their presence, will be mentioned. General advice on modeling noise sources, and its effect on statistical inference via loss of degrees of freedom, and non-orthogonality of regressors, is given. Lastly, different strategies for assessing the benefit of different approaches to physiological noise modeling are presented.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3790256PMC
http://dx.doi.org/10.3389/fnhum.2013.00623DOI Listing

Publication Analysis

Top Keywords

fmri data
20
physiological noise
16
correct presence
8
based independent
8
physiological
6
fmri
6
data
6
noise
5
noise brainstem
4
brainstem fmri
4

Similar Publications

Assessing myocardial viability is crucial for managing ischemic heart disease. While late gadolinium enhancement (LGE) cardiovascular magnetic resonance (CMR) is the gold standard for viability evaluation, it has limitations, including contraindications in patients with renal dysfunction and lengthy scan times. This study investigates the potential of non-contrast CMR techniques-feature tracking strain analysis and T1/T2 mapping-combined with machine learning (ML) models, as an alternative to LGE-CMR for myocardial viability assessment.

View Article and Find Full Text PDF

Morphological characterization of retinal development from birth to adulthood via retinal thickness assessment in mice: a systematic review.

Exp Eye Res

January 2025

Institute of Biomedical Engineering, University of Montréal, Montréal, Canada; Research Center, CHU Sainte-Justine University Hospital Centre, Montréal, Canada; Department of Radiology, Radio-oncology and Nuclear Medicine, University of Montréal, Montréal, Canada. Electronic address:

The morphology and thickness of the retinal layers are valuable biomarkers for retinal health and development. The retinal layers in mice are similar to those in humans; thus, a mouse is appropriate for studying the retina. The objectives of this systematic review were: (1) to describe normal retinal morphology quantitatively using retinal layer thickness measured from birth to age 6 months in healthy mice; and (2) to describe morphological changes in physiological retinal development over time using the longitudinal (in vivo) and cross-sectional (ex vivo) data from the included studies.

View Article and Find Full Text PDF

Introduction: A significant proportion of newly diagnosed prostate cancer (PCa) cases are slow growing with a low risk of metastatic progression. There is a lack of data concerning the optimal biopsy regimen for improving diagnosis yield in PI-RADS3 lesions. This study aimed to assess the diagnostic value of current biopsy regimens in PI-RADS 3 lesions and identify clinical predictors to improve clinically significant PCa (csPCa) detection.

View Article and Find Full Text PDF

Effect of BSSRO on disc-condyle relationship of the temporomandibular joint in skeletal Class III malocclusion patients.

J Stomatol Oral Maxillofac Surg

January 2025

Nanjing Stomatological Hospital, Affiliated Hospital of Medical School, Institute of Stomatology, Nanjing University, Nanjing, China. Electronic address:

Purpose: To analyze dynamic and static changes in the disc-condyle relationship in patients with skeletal Class III malocclusion after orthognathic surgery.

Methods: The surgical group comprised 30 patients with skeletal Class III malocclusion, and the magnetic resonance imaging and mandibular movement data were obtained at T0 (preoperatively), T1 (3 months postoperatively), and T2 (at the end of orthodontic treatment). The control group included 20 patients with normal occlusion, and the mandibular movement data were recorded.

View Article and Find Full Text PDF

A prospective, phase II, neoadjuvant study based on chemotherapy sensitivity in HR+/HER2- breast cancer-FINEST study.

Cancer Commun (Lond)

January 2025

Department of Breast Surgery, Key Laboratory of Breast Cancer in Shanghai, Fudan University Shanghai Cancer Centre, Shanghai, P. R. China.

Background: Hormone receptor-positive (HR+)/humaal growth factor receptor 2-negative (HER2-) breast cancer, the most common breast cancer type, has variable prognosis and high recurrence risk. Neoadjuvant therapy is recommended for median-high risk HR+/HER2- patients. This phase II, single-arm, prospective study aimed to explore appropriate neoadjuvant treatment strategies for HR+/HER2- breast cancer patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!