Background: The purpose of this paper is to report our experience of Descemet's stripping and non-Descemet's stripping automated endothelial keratoplasty (DSAEK/nDSAEK) for microcorneas using 6.0 mm donor grafts.
Methods: Three eyes of two patients (a 56-year-old woman and a 59-year-old woman) with microcornea and suffering from bullous keratopathy were treated with either DSAEK or nDSAEK. A small donor graft (6.0 mm) was inserted into the anterior chamber using a double glide (Busin glide and intraocular lens sheet glide) donor insertion technique. Both patients were followed for at least 12 months. Clinical outcomes, including intraoperative and postoperative complications, visual acuity, and endothelial cell density were evaluated.
Results: In all three cases (100%), no intraoperative complications were noted. In one case with a flat keratometry value (32.13 D), a partial donor detachment was noted one day postoperatively, but it was reattached by rebubbling. In another case, rejection was noted 8 months postoperatively, but treatment with systemic corticosteroids was successful. A clear cornea remained in all three cases (100%), with best-corrected visual acuity greater than 20/100 (mean 20/50) at 12 months. Mean postoperative endothelial cell counts were 2,603 ± 18 cells/mm(2) at 6 months (7.4% decrease from preoperative donor cell counts) and 1,799 ± 556 cells/mm(2) at 12 months (36.5% decrease).
Conclusion: We report for the first time the successful use of a small donor graft (6.0 mm) for DSAEK/nDSAEK in cases of microcornea. Additional stud ies using a large number of patients are required to evaluate fully the potential advantages and drawbacks of small diameter donor grafts for microcornea.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3792923 | PMC |
http://dx.doi.org/10.2147/OPTH.S50299 | DOI Listing |
Cornea
January 2025
Department of Ophthalmology, Saitama Medical University, Saitama, Japan.
Purpose: This study aimed to describe a novel technique of direct anterior chamber (AC) air replacement (DACAR) for the management of Descemet stripping automated endothelial keratoplasty (DSAEK) in postvitrectomized eyes and eyes with previous glaucoma surgery.
Methods: DACAR was performed after a corneal donor graft was transplanted through a wound using the pull-through technique. DACAR involves stabilizing the graft with forceps while introducing air into the AC via an infusion cannula to ensure complete air exchange.
Klin Monbl Augenheilkd
January 2025
Ophthalmology, Amsterdam UMC, Amsterdam, Netherlands.
Background: Refractory corneal edema is the foremost reason for endothelial corneal transplantation (EK) in the world. Descemet membrane endothelial keratoplasty (DMEK) and Descemet stripping automated endothelial keratoplasty (DSAEK) offer good clinical outcomes. However, human donor tissue is limited in availability and has a complex logistical chain.
View Article and Find Full Text PDFSci Rep
January 2025
Eye Center, Medical Center, Faculty of Medicine, University of Freiburg, Kilianstraße 5, 79106, Freiburg, Germany.
Fuchs Endothelial Corneal Dystrophy (FECD) is the most frequent indication for corneal transplantation, with Descemet membrane endothelial keratoplasty (DMEK), Descemet stripping automated endothelial keratoplasty (DSAEK), and penetrating keratoplasty (PK) being viable options. This retrospective study compared 10-year outcomes of these techniques in a large cohort of 2956 first-time keratoplasty eyes treated for FECD at a high-volume corneal transplant center in Germany. While DMEK and DSAEK provided faster visual recovery (median time to BSCVA ≥ 6/12 Snellen: DMEK 7.
View Article and Find Full Text PDFCornea
November 2024
Price Vision Group, Indianapolis, IN.
Purpose: To evaluate Descemet membrane endothelial keratoplasty (DMEK) for failed endothelial keratoplasty (EK).
Methods: We reviewed 362 consecutive DMEK cases for failed EK (Descemet stripping endothelial keratoplasty (DSEK) or DMEK), 118 for early EK failure, and 244 for late failure in 333 eyes of 323 patients without penetrating keratoplasty. Rejection and graft survival rates were assessed with Kaplan-Meier analysis.
J Clin Med
December 2024
Ophthalmology Unit-Eye Bank of Rome, San Giovanni Addolorata Hospital, 00184 Rome, Italy.
To evaluate the clinical outcomes of cornea transplantation (penetrating keratoplasty, Descemet membrane endothelial keratoplasty, Descemet stripping automated endothelial keratoplasty, and deep anterior lamellar keratoplasty) using donor corneas stored in Eusol-C hypothermic storage medium compared to corneas stored in organ-culture. : The clinical outcomes of 92 patients who underwent corneal transplantation with human donor corneas stored in Eusol-C medium at 2-8 °C were retrospectively evaluated. The control group consisted of 169 patients who received corneas organ-cultured at 31 °C.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!