A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comprehensive vertebral deformity and vertebral fracture assessment in clinical practice: intra- and inter-reader agreement of a clinical workflow tool. | LitMetric

Comprehensive vertebral deformity and vertebral fracture assessment in clinical practice: intra- and inter-reader agreement of a clinical workflow tool.

Spine (Phila Pa 1976)

*Department of Radiology, University of Foggia, Viale Luigi Pinto, Foggia, Italy †Department of Radiology, Scientific Institute Hospital "Casa Sollievo della Sofferenza," Viale Cappuccini, San Giovanni Rotondo, Foggia, Italy ‡Optasia Medical Ltd, Mellor House, Cheadle Hulme, Cheadle, United Kingdom; and §Optasia Medical Inc, Sudbury, MA.

Published: December 2013

Study Design: Study design randomized intra- and inter-reader reproducibility study.

Objective: To evaluate reproducibility of quantitative morphometry (QM) and agreement of dichotomous fracture/no-fracture status on lateral spinal radiographs acquired during routine clinical practice using a clinical workflow tool.

Summary Of Background Data: Several recent guidelines have underlined the importance of Genant semi-quantitative scoring and selective QM to confirm and grade suspected vertebral fractures in clinical practice.

Methods: Thoracic and lumbar spine radiographs were acquired from 98 consecutive subjects (mean age, 60.1 ± 11.7 yr) attending the clinic for osteoporosis evaluation. For each subject, QM and Genant semi-quantitative scoring were performed on all evaluable vertebrae from L4 to T4 using a software workflow tool. A radiologist and an experienced radiographical technician performed 2 repeat reading sessions of the radiographs 12 months apart, blinded to each other's results; for the second read, the cases were anonymized and the order was randomized.

Results: Inter-reader reproducibility results were 3.1% and 3.2% coefficient of variation (%) for heights, 0.030 and 0.031 root mean square standard deviation for height ratios. For intrareader reproducibility, these values were 2.2% and 3.5% coefficient of variation %; 0.023 and 0.034 root mean square standard deviation. Kappa score results for agreement of dichotomous fracture/no-fracture status were 0.67 and 0.72 (inter-rater) and 0.50 and 0.67 (intrarater).

Conclusion: The software assessed in this study is a reliable clinical tool that facilitates QM and Genant semi-quantitative scoring of the spine in routine clinical practice.

Level Of Evidence: 3.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BRS.0000000000000048DOI Listing

Publication Analysis

Top Keywords

genant semi-quantitative
12
semi-quantitative scoring
12
clinical practice
8
intra- inter-reader
8
clinical workflow
8
workflow tool
8
study design
8
inter-reader reproducibility
8
agreement dichotomous
8
dichotomous fracture/no-fracture
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!